Quadra-Fire 31M-ACC-MBK Stove User Manual


 
July 7, 2011
7033-277I
Page 19
3100 Wood Stove Series (ACC)
R
D. Chimney Termination Requirements
Follow manufacturers instructions for clearance, securing,
ashing and terminating the chimney.
Must have an approved and listed cap
Must not be located where it will become plugged by
snow or other material
Must terminate at least 3 feet (91cm) above the roof
and at least 2 feet (61cm) above any portion of the
roof within 10 feet (305cm).
Must be located away from trees or other struc-
tures
These are safety requirements and are not meant to assure proper fl ue draft.
Figure 19.1
E. 2-10-3 Rule
Figure 19.2
NOTE:
Chimney performance may vary.
Trees, buildings, roof lines and wind conditions affect
performance.
Chimney height may need adjustment if smoking or
overdraft occurs.
3 ft. (91cm)
Minimum
Less than 10 ft. (305cm)
2 ft. (61cm)
3 ft. (91cm)
Minimum
10 ft. (305cm) To Nearest Roofline
2 ft. (61cm)
Pitched Roof
10 ft. (305cm) or more
3 ft. (91cm) Minimum
Less than 10 ft. (305cm)
2 ft. (61cm)Minimum
3 ft. (91cm) Minimum
Wall or Parapet
Flat Roof