Pfaff 574 Sewing Machine User Manual


 
Adjustment
53
1.06.07 Releasing the tension
Requirement
When the magnet is activated, tension discs 3 must be at least 0.5 mm apart.
Activate the magnet.
Detach the tension bearing plate 1 and adjust pressure plate 2 in accordance with the re-
quirement.
It is possible to set the time for releasing the tension with the parameter
functions, see Chapter 1.08 Parameter settings.
Fig. 1 - 44
61-043
0,5 mm
2
1
3