Pella 81AK0101 Window User Manual


 
5
DOOR REPLACEMENT IN SIDING
WITHOUT NAIL FIN (continued):
Fastening Door to Opening
I. After setting the door plumb level & square, secure the door to the opening. If using
frame screw method then have two people hold the door upright and secure while a
third person opens one panel and inserts a screw through the jamb 6" down from the top
corner, then open the other panel and repeat on the opposite jamb. See below for pilot
hole, screw size, & location details.
6"
16" MAX
O.C.
16" MAX
O.C.
16" MAX
O.C.
16" MAX
O.C.
6"
6"
6"
6"
6" 6"
6"
DOUBLE OPERABLE
6"
6"
16"
MAX.
O.C.
3P
6"
6"
16"
MAX.
O.C.
3P
3P
3P
16" MAX
O.C.
16" MAX
O.C.
6"
6"
6" 6"
SINGLE FIXED OR OPERABLE
6"
6"
16"
MAX.
O.C.
6"
6"
16"
MAX.
O.C.
6"
6"
16"
MAX.
O.C.
6"
6"
16"
MAX.
O.C.
16" MAX
O.C.
6"
6"
3" 3"
6"
6"
16" MAX
O.C.
6"
6"
3" 3"
6"
6"
3P
3P
ALTERNATE ANCHORING METHODS, CLIP AND SCREW PLACEMENT:
Out-Swing Screw Locations In-Swing Screw Locations
5I
5I
5I
5I
5I
5I
Vent Placement
Fixed Placement
Fixed and Vent
Placement
Vent Placement
Vent Placement
Fixed Placement
Fixed Placement
Out-Swing Screw Locations In-Swing Screw Locations