These instructions were tested and developed for replacing windows in wood-frame wall
construction systems designed to manage moisture. This method of installation involves removing
the sash, frame stops and frame hardware from the existing window. The original window frame
will remain in place. If the existing window frame shows signs of water infiltration or is damaged
beyond repair, this method should not be followed and the entire existing window should
be removed. Installation recommendations for other types of wall construction, wall systems,
conditions, multiple windows or bow/bay windows, may be obtained from Pella Corporation or a
local Pella retailer. Building designs, construction methods, building materials, and site conditions
unique to your project may require an installation method different from these instructions and
additional care on your part. Determining the appropriate installation method is the responsibility
of you, your architect, or other construction professional.
CAUTION: Many windows in older homes are painted with lead-based paint. Removal of old
windows may disturb this paint. Proper precautions must be taken to minimize exposure to dust
and debris. Consult state or local authorities for more information.
EXTERIOR
REPLACEMENT WINDOW
INSTALLED
EXTERIOR
INSERT REPLACEMENT
WINDOW
EXISTING WINDOW
EXTERIOR
REMOVE EXISTING
SASH and STOPS
EXTERIOR
Always read the Vinyl Window and Door Limited Warranty before purchasing or installing
Vinyl Windows and Doors manufactured by Pella Corporation. By installing this product,
you are acknowledging that this Limited Warranty is part of the terms of the sale. Failure to comply with all
Pella installation and maintenance instructions may void your Pella product warranty. See Limited Warranty for
complete details at http://warranty.pella.com.
Part Number: 80YV0102© 2009 Pella Corporation
WINDOW REPLACEMENT INSTRUCTIONS FOR
SINGLE-HUNG, DOUBLE-HUNG, CASEMENT, AWNING
INTO EXISTING CASEMENT FRAME USING FRAME SCREWS
YOU WILL NEED TO SUPPLY:
•CedarorImperviousshims/spacers(12to20)
•Closedcellfoambackerrod/sealantbacker
(12to30ft.)
•Pella
®
SmartFlash
™
foil backed butyl window
and door flashing tape or equivalent
•PellaWindowandDoorInstallationSealantor
equivalent high quality, multi-purpose sealant
(1tubeperwindow)
•Lowexpansion,lowpressurepolyurethane
insulating window and door foam sealant.
DO NOT use high pressure or latex foams
•#8x2-1/2"Woodscrews
(6to10perwindow)
TOOLS REQUIRED:
•Tapemeasure
•Level
•Sealantgun
•Prybar
•Utilityknife
•Puttyknife
•Hammer
•Screwdrivers(Flat&Phillips)
•Adjustablepliers
•Sidecutter
•Roto-tool,reciprocatingsaw
•Woodchisel
•1/8"drillbit
•Drill
Installation will require two or more persons
for safety reasons.
SEALANT