5. Set the auxiliary to activate:
a. Use the joystick to position the cursor beside ACTIVATE AUX.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the following available selections.
NO (default) Not activated.
1 An alarm action will close AUX 1.
2 An alarm action will close AUX 2.
d. Press Iris Open to enter selection.
NOTE: The AUX 1/AUX2 will stop when all the alarms assigned to it have cleared. If the
AUX1/AUX is set up as momentary, then it will be activated each time a new alarm is
activated.
6. Set the alarm contact:
a. Use the joystick to position the cursor beside ALARM CONTACT.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the following available selections.
N/O (default) Normally open
N/C Normally closed
d. Press Iris Open to enter selection.
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<AUX>
<TITLE TEXT>
<ALERT>*
<CLEAR>
<PASSWORD>
BACK
EXIT
DOME SETTINGS
EXIT
SPECTRA III
LANGUAGE ENGLISH
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<DOME SETTINGS>
ACK ALERT*
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
BACK
EXIT
RESUME OFF
SEQUENCE (SECS) 5
RESET DELAY (SECS) 0
<ALARM SETTINGS>
ALARMS
*This setting only applies to
Pressurized Spectra III SE dome
systems with software version
1.25 or higher.
(See page 11)
Quick Programming Guide
BACK
EXIT
ALARM SETTINGS
ALARM NUMBER 1
ALARM PRIORITY LOW
ALARM ACTION NONE
ACTIVATE AUX NO
ALARM CONTACT N/O
C2445M-E.pmd 12/14/05, 8:45 AM43