Pelco C3426M-A (5/07) Home Security System User Manual


 
12 C3426M-A (5/07)
6. Connect the power wires.
AC operation only:
If you are wiring more than one Camclosure to the same transformer,
connect one side of the transformer to the red wire on all units; connect the other side of the
transformer to the black wire on all units.
NOTE:
Failure to connect all AC powered units the same way will cause the cameras to be out
of phase with each other and may produce a vertical roll when switching between cameras.
7. Reinstall the back box inside the cover. For vandal-resistant installations, rotate the back box
to position the conduit plug opposite the notch on the side of the cover. Use the two
8-32 x 0.375-inch Phillips pan head screws and washers (removed earlier) to secure the back
box to the cover.
Figure 3.
4S Electrical Box Installation
Voltage Red Wire Black Wire
12 VDC + Ground
24 VAC ~ ~
8-32 X 0.75-INCH
PHILLIPS FLAT
HEAD SCREWS
(SUPPLIED)
8-32 X 0.375-INCH
PHILLIPS PAN HEAD
SCREWS WITH WASHERS
(SUPPLIED)
COVER
BACK BOX
8-32 X 0.375-INCH
PHILLIPS PAN
HEAD SCREWS
(SUPPLIED WITH
ICS110-AP)
CEILING/
WALL
4S STANDARD
ELECTRICAL BOX
ADAPTER PLATE