PGS TC36 AR Indoor Fireplace User Manual


 
4 36ARB2 050505-36
Minimum Clearances to Combustibles:
Side standoffs ......................0 in. (0 mm)
Back standoffs ..................... 0 in. (0 mm)
Top standoffs .......................0 in. (0 mm)
Bottom of appliance .............0 in. (0 mm)
Adjacent sidewall .................4 in. (102 mm)
Ceiling to appliance ...........24 in. (610 mm)
*Mantel to appliance ..........See Figure #2
**Maximum
Mantel extension ..........See Figure #2
Mantel support .....................4 in. (102 mm)
Vertical vent pipe ...........1-3/4 in. (45 mm)
Horizontal vent pipe
Top ...........................1-3/4 in. (45 mm)
Sides ........................1-3/4 in. (45 mm)
Bottom ......................1-3/4 in. (45 mm)
Fig. # 3
CEILING
ADJACENT
WALL OR
MANTEL
SUPPORT
MANTEL
UNIT MAY BE RECESSED UP TO
6" WITH NON-COMBUSTIBLE
MASONRY TYPE MATERIAL
D
E
F
C
B
A
A 9" D 12"
B 6" E 6 3/4"
C 3" F 1 1/2"
COMBUSTIBLE FRAMING AND
FINISH WALL ABOVE STANDOFFS
STANDOFFS
STEEL FRAMING
FIREPLACE FRONT
TOP OF LINTEL BAR
MANTEL CLEARANCE CHART
REF.
MANTEL
DEPTH
REF.
MANTEL
CLEARANCE
Fig. # 2
*
**
MAY USE COMBUSTIBLE FACING
MATERIAL IN THIS AREA
NON-COMBUSTIBLE
FINISH MATERIAL
SEE FIG #7
NON-COMBUSTIBLE ZONE.
DO NOT INSTALL ANY
COMBUSTIBLE MATERIAL,
ELECTRICAL WIRING OR
GAS PLUMBING IN THIS
AREA.