PGS TC36 AR Indoor Fireplace User Manual


 
12 36ARB2 050505-36
Vent pipe:
Install vent pipe through the wall thimble and attach to  ue
outlet collar on top of the  replace. Secure all joints with screws
and seal with approved "High Temp." self-adhesive aluminum
tape provided (see VENT PIPE SEALANT section).
The  replace position may need to be adjusted to ensure
that the vent pipe does not protrude beyond the outer
wall or be recessed any more than 12 inches with the
inner pipe.
Wall vent terminal:
1) Engage the 8" vent collar with the vent pipe and slide
terminal into place. Attach the terminal to the outside
wall. The vent terminal must not be recessed into the
exterior wall or siding.
2) Caulk in place to prevent any moisture entering the build-
ing.
NOTE: MINIMUM CLEARANCES TO THE VENT TERMINAL
MUST BE MAINTAINED (see Fig. #
17).
Fig. #16
HORIZONTAL
TERMINAL
TCVT.9360
14 1/2" FRAMED
OPENING
* Minimum height from the  oor to center of
the opening with a maximum horizontal run
of 18" using TC Vent. The height will need to
be increased with a longer horizontal run .
WALL SHIELD
THIMBLE
TCVT.THIMA
ELBOW
TCVT.811XLB90
*
INSULATED
COLLAR
SHIELD
TC36.9709
24" VENT PIPE
TCVT.811X24
12" VENT PIPE
TCVT.811X12