PGS TC36 AR Indoor Fireplace User Manual


 
050505-36 36ARB2 25
Fig. # 35
THERMOCOUPLE
THERMOPILE
PILOT FLAME
ELECTRODE
APPENDIX A
MAINTENANCE
Caution: Turn off gas and electrical power supply (if appli-
cable) and allow ample time for unit to cool before servicing
appliance. It is recommended that the  replace and its vent-
ing should be inspected at least once a year by a quali ed
service person.
Glass Panel:
Warning: Do not operate  replace with glass panel removed,
cracked or broken. Replacement of the glass panel should be
done by a licensed or quali ed service person.
Do not strike or otherwise impact the glass in anyway that may
cause it to break. If the glass becomes cracked or broken,
it must be replaced before using the  replace. Replacement
glass can be obtained from your nearest Town and Country
Fireplaces
TM
dealer. The size required is 36" x 30" x 5mm.
Use ceramic glass only. Do not substitute with any other
type.
To remove broken glass, remove window frame as noted in
"Window Frame Removal" section.
Unclip the Glass Retainer Clips located at the top of the Win-
dow Frame. Pull the top edge of the glass out of the frame
 rst, then lift it up and out of the bottom edge.
Install the new piece of glass with the gasket into the frame
so that the thicker bead of gasket faces the  replace.
Annual Inspection:
a) Remove glass panel and log set. Inspect logs and burner
assembly for soot buildup. If excessive buildup of soot is
present, have a quali ed service person inspect and adjust unit
for proper combustion. Clean logs and burner with a brush or
vacuum cleaner, paying close attention to burner ports.
b) Check the pilot system for proper  ame size and opera-
tion. Clean pilot free of soot, dust or any other deposits. (See
Fig. #35 and 36)
c) Check that the vent pipe and vent terminal are open and
free from blockage or debris. If the venting is disassembled
for cleaning, it must be properly assembled and re-sealed.
Refer to VENTING section for proper procedure.
d) Check glass panel gasket, replace if necessary. It is important
that the glass seal be maintained in good condition.
e) Check and replace batteries as needed.
Note: The appliance area must be kept clear and free from
combustible materials, gasoline and other  ammable vapours
and liquids.
Periodically:
a) Viewing glass may be cleaned as necessary with  replace
glass cleaner.
b) Exterior  nish may be cleaned with mild soap and water.
CAUTION:
Do not use abrasive cleaners on glass or any other
part of the  replace.
Do not clean glass when hot.
PILOT FLAME
FLAME SENSOR
ELECTRODE
Fig. # 34
MILLIVOLT PILOT
ELECTRONIC PILOT