Pacific Digital Upright Vacuum Cleaner Vacuum Cleaner User Manual


 
10
Place the three tabs on bottom plate
into slots in front of cleaner body.
Snap bottom plate into place over
agitator.
Slip agitator through new belt (with
lettering toward outside of clean-
er) and position belt in belt guide
(D). Push end of belt into opening in
cleaner body.
Reposition agitator making sure to
align flat sides of projection (E) on
belt end of agitator with flat sides of
slot (F) in cleaner body.
Remove agitator and broken agitator
belt.
(If belt is not broken but is stretched
or cut, proceed with steps for Figs.
50 to 53 and pull belt off motor pul-
ley. Then continue with Fig. 48).
47
49
48
How to replace
Disconnect cleaner from electrical
outlet.
Place handle in operating position
and turn cleaner over so bottom
side is up.
To remove bottom plate remove
screws (A), insert end of flat screw-
driver into wide area of right-hand
slot (B) and push handle of screw-
driver to the rear. Repeat in left-hand
slot (B).
Lift extension (C) of bottom plate,
rotate plate and remove from clean-
er body.
The belt
The belt on your cleaner causes the
agitator to rotate and is important for
the effective operation of the cleaner.
The belt is located under the bottom
plate of the cleaner and should be
checked from time to time to be sure
it is in good condition.
When to replace
To check belt, remove bottom plate
and hood as shown in “How to
replace belt.” Replace belt if it is
stretched, cut or broken.
What to buy
To assure effective operation, use
only genuine Pacific Floor belts with
your cleaner. When purchasing a
new belt, ask for part No. 38528040.
Hold new filter bag as shown. Align
opening in filter bag with dirt tube (B).
Push bag collar (A) firmly onto tube
(B).
Tuck in filter bag; zip outer bag.
A
B
D
F
E
A
C
A
B
B
45
46