Make certain the heater has fully cooled (approximately 25 minutes) before opening the door and conducting service.
!
WARNING
The fi re box becomes very hot during operation. Let the heater cool completely before conducting service.
!
WARNING
To clean the burn pot, open the door and knock away any debris on the burn
pot. If severely clogged, remove the burn pot to gain better access.
If removing the burn pot set aside on a non-combustible surface. See Figure
40. Once removed, discard all material that has accumulated in the burn pot.
Make certain that all openings are clear of any build up of ash from the ledge
below the burn pot.
CLEANING THE BURN POT
Re-install the burn pot ensuring it sits level
in the heater. Also must ensure the ignitor
and the burn pot locating notch line up
when reinstalling the burn pot.
Figure 40
The more frequently you clean out the fl y ash, the more effi cient your heater will burn.
1. Open the viewing door. See Figure 35 and 36
2. Lift the burn pot out and set aside on a non-combustible surface.
See Figure 40. Remove the right and left louvres by lifting the louvres up
and out of the fi rebox setting them on a non-combustible surface.
VACUUM FIREBOX
Figure 41
IGNITOR
LOCATING NOTCH
LOUVRES
AIR HOUSING
FIREBOX
BI-WEEKLY (OR EVERY 10 BAGS OF PELLETS)