Napoleon Fireplaces NPI40 Air Conditioner User Manual


 
W415-0616 / C / 06.04.08
25
TRIVET NPI40
The trivet for the NPI40 is attached by two set screws on the inside of the hopper
lid.
Figure 32
INSTALL VIEWING DOOR NPS40 AND NPI40
Figure 33
(Insert
Illustrated)
The main viewing door has been boxed separate from the heater, but MUST be installed before burning
the heater.
1. Open both side panels, exposing the bushing on the left and the latches on the right.
2. Align the pins on the door to the bushing on the left side of the heater.
Lower into place until both bushings touch.
3. Engage the latch hooks into the door frame. Snap the rear handle hook to
lock the latch closed.
Before loading pellets into the hopper fi rst transfer the pellets from it's original plastic bag to a metal bucket.
NOTE: If the pellets are kept in the plastic bag, the bag may come in contact with the heater causing the bag to
melt and the pellets to spill.
DO NOT load pellets into the hopper if they have been exposed to moisture. Moisture can cause pellets to swell and
cause blockage in the feed system. Thoroughly dry pellets before placing into hopper.
PROPER PELLET LOADING
LIGHTING HEATER MANUALLY
Your heater can be lit manually without using the automatic igniter by following the procedure below.
1. Press the start switch
2. Turn feed dial to "Optimum"
3. Place a "handful" of pellets into the burn pot.
4. Cover with a small amount of approved (non-volatile) fi re starter gel.
5. Light fi re starter with a match and close the viewing door.
Heater may be hot.
Other than placing a handful of pellets in the burn pot for lighting manually, never feed pellets through the
glass viewing door. An "OVERFIRE" condition could occur, if more pellets enter the fi rebox then what the feed
tube can deliver. Pellets must only be burned within the burn pot.
!
WARNING