MINIMUM CLEARANCES TO COMBUSTIBLES
Side wall to unit 8"
Maximum mantel depth 10"
Mantel to top of unit 8"
Top facing to unit 6 3/8"
Side facing to unit 6"
Floor protection* 6"*
* Floor Protection: Minimum 6" in front of door and to either
side.
MINIMUM MANTEL CLEARANCES
REAR TO TOP VENT CONVERSION INSTRUCTIONS
NOTE: The insert is factory shipped in a rear vent confi guration.
1. To vent exit vertically, remove the two screws holding the exhaust cover.
NOTE: Be careful not to damage the gasket.
2. Remove the two screws holding the exhaust tube
NOTE: Be careful not to damage the gasket.
3. Attach the exhaust tube and gasket in the vertical position.
4. Attach the exhaust cover and gasket over the horizontal exit.
Figure 18
Exhaust Tube
Exhaust Cover
Figure 20
Figure 19