5. FAN SPEED SETTING
This function controls the speed of the hot air circulating fan.
To change the fan speed, use the UP and Down button until
the cursor (small triangle) is left of the fan icon. Set to one of
4 levels included or turned off (level 4 means full speed)
6. TIMER SETTING
The Remote Control has a sleep function. With this function
it is possible to set a sleep time. After this time has elaspsed
the appliance is automatically switched off. To activate the
function use the UP and DOWN button until the cursor (small
triangle) is to the left of the clock icon.
Then use the right or left button to set the desired sleep time.
It is possible to set a maximum time of 90 minutes with 15
minutes steps. After the desired time has been set press the
UP or DOWN key to start the timer. (Figure 58)
7. AUXILIARY OUTPUT
The auxiliary function allows switching of the accent light
accessory on or off.
To control the accent light use the UP and DOWN button
until the cursor (small triangle) is to the left of the AUX word.
The right button turns the light on and the left button turns it
off. (Figure 59)
CHILD SAFETY LOCK-OUT
This function is to deactivate con-
trol button. The function is active
when the lock icon is lit. To activate
this function press the ON / OFF
button and within one second the
UP key
To reactivate the remote control
buttonss follow the same se-
quence, press ON / OFF key and
within one second press the UP
button.
POWER FAILURE
During main power loss it is not possible to turn on the appli-
ance with the Remote Control. It is possible to turn the appli-
ance on manually using the Backup switch of the Receiver
set to the MAN position. (Figure 53) The receiver is located
in the control area (see steps 1 and 2 or page 19 - Once the
main power has been restored the receiver must be returned
to the auto position for remote control.
NOTE: On subsequent restoration of the main power and with
the BACKUP switch in AUTO position, the Receiver leaves
the appliance turned off even if the Remote Control is turned
on. In this case, to switch on the appliance, press the ON /
OFF button of the Remote Control twice.
LOW BATTERY DETECTION
The duration of the batteries de-
pends on many factors: the quality
of the batteries used, the number
of ignitions of the appliance, the
number of changes to the flame
height etc.
When the transmitter batteries are
low, an icon will be displayed on the
LCD display to alert of a low bat-
tery condition before losing battery
power at all. As soon as the depleted
batteries are replaced, the transmit-
ter will restart its normal operation.
FIGURE 43
FIGURE 44
FIGURE 45
FIGURE 47
FIGURE 46