Napoleon Fireplaces BGD90PT Indoor Fireplace User Manual


 
19
W415-0614 / A / 07.24.07
RECEIVER
SLOT
SPARK MODULE
VALVE
WING NUT
1. Remove access panel from inside the fi rebox.
2. Unplug the control module from the junction box
3. Pull up on the control module being held down with velcro
and disconnect the plugs (fan, aux). Remove wiring harness
from the front of casing.
4. Install the new control module (see schematic Pg.14).
CONTROL MODULE REMOVAL
REMOTE AND VALVE ACCESS
The valve on The is piped with two fl ex connec-
tors
(one inlet, one outlet).
It can be removed or pulled forward for service.
1. Open right control door.
2. Remove the wing nut and pivot the valve out from the
slot at the bottom of the valve.
3. Slowly pull the valve through the control door being careful
not to kink the gas lines or wires.
VALVE REMOVAL
Follow the door removal instructions. Remove the right side
panel. Remove the four screws from the access door.
Note: A new gasket will be required, when re-installing
the access panel (see replacement parts).
INNER ACCESS PANEL
1. Open the right control door by pulling bottom portion away
from magnet catch.
2. Remove the hearth strip by lifting up and away from unit.
3. Remove the receiver by pulling the left side of the plate
away from the bracket.
4. Once disengaged pull the wiring harness out from the
back of receiver.
FIGURE 38
The control area can be accessed either through the control door or through the access panel inside the fi rebox.
REMOTE RECEIVER REMOVAL
RECEIVER
SLOT
SPARK MODULE
VALVE
WING NUT
“AUTO SPARK” BATTERY REMOVAL
1. Open the right control door by pulling bottom portion away
from magnet catch.
2. Remove the hearth strip by lifting up and away from unit.
3. The spark module is located in the front right corner of the
unit (see photo below).
4. Disengage the battery compartment door from the top of
module.
5. Replace battery and re-install compartment door.