Napoleon Fireplaces BGD90PT Indoor Fireplace User Manual


 
13
W415-0580 / C / 04.07.08
FLUE COLLAR
RESTRICTOR
PLATE
FIGURE 23
FIGURE 24
WARNING
THE STANDOFFS HAVE
BEEN SHIPPED FLAT.
BEFORE FRAMING
ENSURE THE STANDOFFS
ARE BENT UP AND
SCREWED INTO PLACE.
ATTENTION ATENCIÓN
LAS TRABAS PERMANECEN
PLANAS DURANTE EL ENVÍO.
ANTES DE LA INSTALACIÓN,
VERIFIQUE QUE LAS TRABAS
SE PLIEGUEN HACIA ARRIBA
Y SE ATORNILLEN
CORRECTAMENTE.
LES ESPACEURS SONT
EMBALLÉS À PLAT. AVANT DE
CONSTRUIRE L'OSSATURE,
ASSUREZ-VOUS QUE LES
ESPACEURS SONT PLIÉS
ET FIXÉS EN PLACE À
L'AIDE DE VIS.
The can be installed with a rectangular opening.
It is best to frame your fi replace after it is positioned and the vent system is installed. Use 2x4’s
and frame to local building codes.
NOTE: In order to avoid the possibility of exposed insulation or vapor barrier coming in contact
with the fi replace body, it is recommended that the walls of the fi replace enclosure be “fi nished”
(i.e.: drywall/sheetrock), as you would fi nish any other outside wall of a home. This will ensure that
clearance to combustibles is maintained within the cavity.
For convenience, the stand-offs have been shipped fl at. Before framing, ensure the stand-
offs are opened and screwed in place.
Vertical terminations may display a very active fl ame. If this appearance is not desirable, the vent exit must
be restricted using restrictor plate, W500-0321. This reduces the velocity of the exhaust gases, slowing
down the fl ame pattern and creating a more traditional appearance.
The plate has a series of holes to allow for adjustment.
Remove the two screws on either side of the exhaust collar inside the fi rebox. Install the plate in the desired
set of holes, then replace the screws.
It is recommended to secure in the third set of holes which causes the greatest amount of restriction for
vent lengths between 15 and 30 feet.
This appliance is certified to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home or mobile
home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This
appliance is only for use with the type(s) of gas indicated on the rating plate. A conversion kit is supplied with the mobile home appliance.
MOBILE HOME
This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. The fireplace is equipped with
two 1/4" diameter holes located in the front left and right corners of the base. For mobile home installations, the fireplace must be fastened in
place. Use #10 hex head screws, inserted through the holes in the base to secure. Always turn off the pilot and the fuel supply at the source,
prior to moving the mobile home. After moving the mobile home and prior to lighting the fireplace, ensure that the logs are positioned
correctly.
This appliance is certified to be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by
local codes. This fireplace is only for use with the type of gas indicated on the rating plate. This fireplace is not convertible for use with
other gases, unless a certified kit is used.
Conversion Kits
The mobile home appliance is field convertible between Natural Gas (NG) and Propane (LP).
To convert from one gas to another consult your Authorized dealer/distributor.
FRAMING
Proceed once the vent installation is complete.
NOTE: All gas connections must be contained within the fireplace when complete.
1. Move the fireplace into position and secure to the floor through the 1/4" holes located at either side of the base.
2. The fireplace is designed to accept 3/8" gas supply line. The fireplace is equipped with a 3/8" manual shut-off valve.
3. Connect the gas supply in accordance to local codes. In the absence thereof, install according to the National Installation Code.
4. When flexing any gas line, support the gas valve so that the lines are not bent or kinked.
5. Check for gas leaks by brushing on a soap and water solution.
Do not use open flame.
Purge all gas lines with the glass door of the fireplace removed. Assure that a continuous gas flow is at the burners before re-installing the
door.
GAS INSTALLATION
It is not necessary to install a hearth extension, but the fi replace should be raised to be fl ush with
either the hearth or the fi nished fl oor.
When roughing in the fi replace, raise the fi replace to accommodate for the thickness of the fi nished fl oor materials, i.e. tile, carpeting, hard
wood, which if not planned for will interfere with the removal of the hearth strip, which must be removed to access the fi rebox. Objects placed
in front of the fi replace should be kept a minimum of 48” away from the front face.
FIGURE 22
RESTRICTING VERTICAL VENTS