Napoleon Fireplaces BGD40-N Indoor Fireplace User Manual


 
26
W415-0299 / J / 04.14.08
Remove the "Z" shaped
mounting bracket secured
to the burner, by the pilot.
Remove the thermodisc from
the bracket supplied in the
blower kit and attach to the
mounting bracket. Attach the
connectors from the black
and white wires to the ther-
modisc.
Do not overtighten thermodisc or distort housing.
Attach the connectors from the
black and red wires to the blower.
Attach and secure the variable
speed switch using the nut pro-
vided. Plug the harness cord into
the receptacle.
The wire harness provided in this kit is a universal har-
ness. When installed, ensure that any excess wire is
contained, preventing it from making contact with mov-
ing or hot objects.
Drywall dust will penetrate into the blower bearings, caus-
ing irreparable damage. Care must be taken to prevent
drywall dust from coming into contact with the blower or
its compartment. Any damage resulting from this condi-
tion is not covered by the warranty policy.
Because the blower is thermally activated, when turned
on, it will automatically start approximately 10 minutes
after lighting the fi replace and will run for approximately
30 - 45 minutes after the fi replace has been turned off.
Use of the fan increases the output of heat.
Position the vibration reducing pad, centred, onto the thread-
ed stud, piercing a hole into the pad. The blower must be able
to be positioned entirely onto the pad.
Tilt the blower onto its side and slide it past the controls.
Position the blower under the clip and onto the stud. Secure
with a wing nut.
FIGURE 59
FIGURE 56
FIGURE 58
FIGURE 60
FIGURE 61
FIGURE 57
The blower bracket contains two holes that allow the blower
to be positioned away from the intended gas supply hole.
OPTIONAL BLOWER INSTALLATION
!
WARNING
INSTALLATION TO BE DONE BY A QUALIFIED IN-
STALLER and must be electrically connected and ground-
ed in accordance with local codes. In the absence of local
codes, use the current CSA C22.1 CANADIAN ELECTRICAL
CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL
CODE in the United States.
Remove the blower
from its mounting
bracket and attach
to the bracket sup-
plied with the fi re-
place. This bracket
is found secured
on the mounting
stud located at the
bottom of the vent
side wall.