Napoleon Fireplaces BGD40-N Indoor Fireplace User Manual


 
21
W415-0299 / J / 04.14.08
FIGURE 41
1. Install the 5" diameter fl ex pipe
to the fi replace. Secure with 3
screws and fl at washers. Seal
the joint and screw holes using
high temp sealant
(not supplied) or Red
RTV Silicone may
also be used in this
location.
2. Install the 8" diam-
eter fl ex pipe to the
fi replace. Attach and
seal the joints.
For optimum per-
formance it is recommended that all horizontal runs have a
¼" rise per foot.
FIREPLACE VENT CONNECTION
GAS INSTALLATION
TOP, FLOOR, SIDES & BACK
DESSUS, PLANCHER, COTES & ARRIERE
RECESSED DEPTH (CORNER INSTALLATION ONLY)
PROFONDEUR D'ENCASTRE (INSTALLATION DU COIN SEULEMENT)
VENT / EVENT 1"
MANTLE HEIGHT / HAUTEUR DU MANTEAU 5"
*
NOT FOR USE WITH SOLID FUEL. FOR USE WITH COVERS AND
GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
WARNING:
DO NOT ADD ANY MATERIALTO THE APPLIANCE, WHICH WILL COME IN CONTACT
WITH THE FLAMES, OTHER THAN THAT SUPPLIED BYTHE MANUFAC TURER WITH THEAPPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS /
DEGAGEMENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET
APPAREIL. UTILISER AVEC LES COUVERTURES ET LES PORTES
VITREES HOMOLOGUEES SEULEMENT AVEC CETTE UNITE.
AVERTISSEMENT:
N'AJOUTEZ PAS A CET APPAREILAUCUN MATERIAU DEVANT ENTRER EN
CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE
FABRICANT.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS. SEE OWNERS
INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND RESEALING IS
NECESSARY AFTER SERVICING THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A WOLF
STEEL. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL
EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN
DU SYSTEME DE PRISE D'AIR.
ELECTRICAL RATING / CLASSIFICATION: 115V, 0.82AMP, 60HZ
OPTIONAL FAN KIT / ENSEMBLE DE VENTILATEUR FACULTATIF: GZ-550KT
0
25¼"
*
MAXIMUM HORIZONTAL EXTENSION / L'EXTENSION HORIZONTALE MAXIMALE: 3". SEE INSTRUC-
TION MANUAL FOR GREATER EXTENSIONS. REFERER AU MANUEL D'INSTRUCTION POUR DES
EXTENSIONS PLUS GRANDES.
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 10 INCHES AND 20 FEET RESPEC-
TIVELY. LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 10 POUCES ET 20 PIEDS
RESPECTIVEMENT.
WOLF STEEL LTD, BARRIE, ON, CANADA
SERIAL NUMBER/NO. DE SERIE:
GD22
MADE IN CANADA / FABRIQUE AU CANADA
BGD40 / BCDV400
W385-0249
CER TIFIED UNDER / HOM OLO GUE SEL ON L ES NORMES: CSA 2.33-2002, ANSI Z21.88-2002 VENTED GAS FIREPLACE HEATER / FOYER DE CHAUFFAGE AU GAZ AVEC EVACUATION
DIRECT VENT GAS FIREPLACE. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE
CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24
CFR, PART 3280. WHEN THIS US STANDARD IS NOTAPPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AN D COMM UNITIES, ANSI /NFPA 501A.
FOYER A GAZ VENTILE DIRECT. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE
SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE
SECURITE ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORME
RELATIVE AU CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA 501A.
MANIFOLD PRESSURE:
3.5" WATER COLUMN
PRESSION AU COLLECTEUR:
3.5" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE:
4.5" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE:
4.5" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE:
7.0" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMAL:
7.0" D'UNE COLONNE D'EAU
ALTITUDE/ELEVATION: 0-4500FT(0-1370m)
INPUT/ALIMENTATION: 30,000 BTU/h
REDUCED INPUT/ALIMENTATION REDUIT:
20,000 BTU/h
ORIFICE: #39
ALTITUDE / ELEVATION: 0-4500FT (0-1370m)
INPUT /ALIMENTATION: 30,000 BTU/h
REDUCED INPUT / ALIMENTATION REDUIT:
20,000 BTU/h
ORIFICE: #52
MANIFOLD PRESSURE:
10" WATER COLUMN
PRESSION AU COLLECTEUR:
10" D'UNE COLONNE D'EAU
MINIMUM SUPPLY PRESSURE:
11" WATER COLUMN
PRESSION D'ALIMENTATION MINIMALE:
11" D'UNE COLONNE D'EAU
MAXIMUM SUPPLY PRESSURE:
13" WATER COLUMN
PRESSION D'ALIMENTATION MAXIMAL:
13" D'UNE COLONNE D'EAU
CANADA
AND
ET
CERTIFIED FOR
CERTIFIEE POUR
USA
MODEL BGD40 - N
MODEL BCDV400 - N
MODEL BGD40 - P
MODEL BCDV400 - P
REFERENCE #15510
FIGURE 42
FIGURE 40
6. Aligning the seams of the
terminal and air terminal connector,
place the terminal over the air
terminal connector making sure
the liner goes into the hole in the
terminal. Secure with the three
screws provided.
7. Apply a heavy bead of
weatherproof caulking 2"
above the fl ashing. NOTE:
Maintain a minimum 2” space
between the air inlet base
and the storm collar. Install
the storm collar around the
air terminal and slide down
to the caulking. Tighten to
ensure that a weather-tight seal between the air terminal
and the collar is achieved.
Proceed once the vent installation is complete.
NOTE: All gas connections must be contained within the fi replace when complete.
1. Move the fi replace into position and secure to the fl oor through the 1/4" holes located at either side of the base.
2. The fi replace is designed to accept 3/8" gas supply line.
3. Connect the gas supply in accordance to local codes. In the absence thereof, install according to the
National Installation Code.
4. When fl exing any gas line, support the gas valve so that the lines are not bent
or kinked.
5. Check for gas leaks by brushing on a soap and water solution.
DO NOT USE OPEN FLAME.
Purge all gas lines with the glass door open. Assure that a continuous gas fl ow is at
the burner before closing the door.