Napoleon Grills GDI-44P Indoor Fireplace User Manual


 
9
W415-0314 / C / 01.15.04
Purge all gas lines with the glass door open. Assure
that a continuous gas flow is at the burner before clos-
ing the door. Allow several minutes (5-15) for the flame
to stabilize after ignition.
Do not operate the main burner of the in-
sert with the door removed.
When lit for the first time, the fireplace will emit a slight
odour for a few hours. This is a normal temporary condi-
tion caused by the "burn-in" of paints and lubricants
used in the manufacturing process and will not occur
again. Simply open a window to sufficiently ventilate
the room. After extended periods of non-operation such
as following a vacation or a warm weather season, the
fireplace may emit a slight odour for a few hours. This is
caused by dust particles in the heat exchanger burning
off. Open a window to sufficiently ventilate the room.
PURGE THE GAS LINE WITH THE GLASS DOOR OPEN.
8. Depress slightly and hold gas knob while lighting the pilot
with the push button ignitor. Keep knob depressed for one
minute, then release. If pilot does not continue to burn, re-
peat steps 3 through 7.
9. With pilot lit, depress and turn gas knob counter-clock-
wise to on.
10. If equipped with flame adjustment valve, push and turn
knob to high.
11. If equipped with remote on-off switch/thermostat, main
burner may not come on when you turn valve to on. Remote
switch must be in the on position to ignite burner.
12. Turn on all electric power to the fireplace.
FLAME ADJUSTMENT
KNOB
ON/OFF KNOB
A. This fireplace is equipped with a pilot which must be lit
by hand. While following these instructions exactly.
B. Before operating smell all around the fireplace area for
gas and next to the floor because some gas is heavier
than air and will settle on the floor.
C. Use only your hand to turn the gas control knob. Never
use tools. If the knob will not turn by hand, do not try to
repair it. Call a qualified service technician. Force or at-
tempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under water.
Immediately call a qualified service technician to inspect
the fireplace and replace any part of the control system
and any gas control which has been under water.
• Turn off all gas to the fireplace.
• Open windows.
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire depart-
ment.
When lighting and re-lighting, the gas knob cannot be turned
from pilot to off unless the knob is depressed slightly.
1. Stop! Read the above safety information on this label.
2. Turn off all electric power to the fireplace.
3. Turn the gas knob clockwise to off.
4. Wait five (5) minutes to clear out any gas. If you smell gas
including near the floor. Stop! Follow "B" in the above safety
information on this label. If you don't smell gas go the next step.
5. If fireplace is equipped with flame adjustment valve turn
clockwise to off.
6. Find pilot located in front of back log.
7. Turn gas knob counter-clockwise to pilot.
2. Push in gas control knob slightly and turn clockwise to
off. Do not force.
1. Turn off all electrical power to the unit if service is to be
performed.
TURN OFF THE GAS AND UNPLUG ELECTRICAL POWER
BEFORE SERVICING THE FIREPLACE INSERT!
CAUTION: Label all wires prior to disconnection when serv-
icing controls. Wiring errors can cause improper and dan-
gerous operation. Verify proper operation after servicing.
This insert and its venting system should be inspected
before use and at least annually by a qualified service per-
son. The fireplace area must be kept clear and free of com-
bustible materials, gasoline or other flammable vapours
and liquids. The flow of combustion and ventilation air must
not be obstructed.
1. In order to properly clean the burner and pilot assembly,
remove the logs exposing both assemblies.
THERMO-
COUPLE
PILOT
BURNER
THERMOPIL
OPERATION / MAINTENANCE
OPERATING INSTRUCTIONS
WHAT TO DO IF YOU SMELL GAS:
FOR YOUR SAFETY READ BEFORE LIGHTING:
LIGHTING INSTRUCTIONS
TO TURN OFF GAS
MAINTENANCE
REAR BURNER CONROL
rear burner control knob
The purpose of the rear burner
is to increase heat output or
BTUs of the unit and will only
operate when the main burner
is functioning. To turn the rear
burner on, simply depress the
burner control knob (located in
the valve compartment at the left
hand side below the piezo igni-
tor) and rotate the knob counter-
clockwise to 'high'.
In order to achieve maximum
turn down rate, the rear burner
must be turned off.