Napoleon Grills GDI-44P Indoor Fireplace User Manual


 
11
W415-0314 / C / 01.15.04
Remove the pilot screw cap. Adjust the pilot screw to pro-
vide properly sized flame. Turn in a clockwise direction to
reduce the gas flow. Replace the pilot screw cap.
FIGURE 22
FIGURE 23
Air shutter adjustment
must only be done by a
qualified gas installer!
FIGURE 25
Closing the air shutter will cause a more yellow flame, but
can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner
ports. The flame may not appear yellow immediately; allow
15 to 30 minutes for the final flame colour to be estab-
lished.
Some vent configurations may display a very active flame.
If this appearance is not desirable, the vent exit may be
restricted using the restrictor plate shown in FIGURE 24.
FIGURE 24
W010-0898
ADJUSTMENTS
PILOT BURNER ADJUSTMENT VENTURI ADJUSTMENT
VENT RESTRICTION
This unit is approved for use with a 2" liner for air intake
and a 3" liner for exhaust. For best performance, however,
it is recommended to use two 3" liners.
Air shutter settings will differ depending on the liner sys-
tem used. Use the charts below to determine the correct
air shutter setting:
3"/ 3" LINER SYSTEM
FRONT REAR
NG 1
/
16
"3
/
16
"
LP 3
/
16
"7
/
16
"
AIR SHUTTER SETTING
2"/ 3" LINER SYSTEM
FRONT REAR
NG 1
/
8
"1
/
4
"
LP 1
/
4
"5
/
8
"
AIR SHUTTER SETTING