Munchkin Gas-Fired Hot Water Circulating Heater Boiler User Manual


 
12
GAS-FIRED HEATER Installation Manual
PART 4: PREPARE MUNCHKIN CONTENDER
(CONTINUED)
D. INSTALLATION STEPS
1) Prior to lifting the Munchkin Contender
Heater onto the wall, use the enclosed
template to level and locate the 2 primary
screws (#12 x 3" [3/16" x 3"]) round head
tapping screw leaving about 1/4" under the
screw head to the wall surface to allow for
access to the keyway slot which is located in
the back of the heater panel. It is extremely
important that the line on the template is level
when locating the first 2 screws. Failure to do
so will result in an uneven or out of level
installation.
2) Remove the Munchkin Contender cover and
locate the 2 keyway slots over the screws,
then lower the heater onto the smallest part
of the keyway slot.
3) Once the heater is mounted on the first 2
screws, finish tightening the first two screws to
the back panel, then install the 6 additional
screws of the same size to the back panel
holes. This will provide additional strength and
support to the Munchkin Contender Heater.
C. MUNCHKIN CONTENDER
WALL MOUNTING INSTRUCTIONS
The wall must be vertically plumb and capable of
carrying the weight of the Munchkin Contender and
its related components.
The building frame (studs) must be 16" on cen-
ter. If not, you must use 1/2" minimum plywood
24" x 48", fastened with at least (14) #12 x 3"
(3/16" x 3") round head tapping screws to the
frame of the building to provide proper support
for the heater. Alternate methods of mounting
must not be used. (ex. toggle bolts, hollow wall
anchors) or any other fastener other than #12 x
3" (3/16" x 3") round head tapping screws.
WARNING
The wall must be capable of carrying the weight
of the heater and its related components. The
weights of the heater are approximately:
MC-50- 71 lbs.
MC-80- 74 lbs.
MC-99-
MC-120-
]]
84 lbs.
Failure to comply with above could result in
severe personal injury, death or substantial
property damage.
WARNING
This heater is heavy and awkward to lift. It is
recommended and safer to install the heater
with two people. Use caution as to not drop the
heater which could cause personal injury. Verify
that the heater is securely mounted before
leaving the heater unsupervised.
CAUTION
If the Munchkin Contender is not vertically
plumb, improper and unsatisfactory operation
may occur. This will cause excessive
condensation build-up causing unnecessary
maintenance and nuisance fault codes.