Monessen Hearth WDV500 Indoor Fireplace User Manual


 
32
78D0011
WDV Series Gas Fireplace



1. Turn on the master switch and wait for a beep.
2. Press the ON button on the Command Center. Pilot will light and burner will come on High setting.

1. If the pilot doesn’t light after sparking for 30 seconds, pilot trial lockout happens. The LED on the Command Center
flashes Green once every 2 seconds, until reset.
2. If the pilot flame is lost during normal operation, flame loss lockout happens. The LED on the Command Center
flashes Red-Green once every 2 seconds, until reset.
3. Turning the master switch OFF, then ON again will reset the system.

1. Press the ON button (on the Command Center) once to turn on the main burner with maximum flame height.
2. Press the OFF button to decrease flame height. The first two presses will decrease the flame height to medium and
low.
3. The third press on OFF will turn off the main burner. In standing pilot configuration, the pilot will stay; in intermittent
pilot configuration, the pilot will be shut off.

There are three ways to turn the fireplace off. (This will turn the entire system OFF.)
1. Flip the master switch to the off (“O”) position
2. Press the OFF button to Medium, Low, then Off.
3. Hold the OFF button anytime for three seconds. This command of OFF will remember all last settings before turning
off. The next time the fireplace is turned on, all settings will resume. (Memory OFF)

The following functions are available on the Command Center.
 
Power Up Flip the master switch to the ON ("_") position to power up the system
Fireplace ON Press the ON button on the Command Center to turn the fireplace on
Fireplace OFF Flip the master switch to the OFF ("o") position OR press the OFF button 3
times OR hold the OFF button 3 seconds (Memory OFF)
Flame Height Up Press the ON button once to turn on the fireplace with maximum flame height
Flame Height Down Press the OFF button to lower the flame height to Medium and Low
 
Conversion Cover Missing One RED (1 time)
Spark Fail Two RED (1 time)
No Sensor Signal Three RED (1 time)
Pilot Lockout - trial One GREEN, every 2 sec. (until manual reset)
Pilot Lockout - flame loss One RED-GREEN, every 2 sec. (until manual reset)
Low Battery One RED, every 10s (continuously)
No or Low Thermopile Power Two RED, every 10s (continuously)
Learning GREEN Flashes, every 1 sec. (for 10 sec.)
AC Power On GREEN solid

The Command Center has a self-diagnostic LED enabling you to troubleshoot problems and potentially avoid a service
call. Please refer to the charts below for indicator reference.