Monessen Hearth WDV500 Indoor Fireplace User Manual


 
78D0011
15
WDV Series Gas Fireplace

A 10’
B 7’
10’
FP2426
max vent run w/elbows
Figure 14 -
Maximum Vent Run with Elbows
A + B = 17' Maximum
90° Elbow = 3'
FP2426
Example: Elbow 1 = 90°
Elbow 2 = 45°
Elbow 3 = 45°
Elbow 4 = 90°
Total Angular Variation = 270°
Figure 15 -
Maximum Elbow Usage
1
2
3
4
1
2
3
4
FP1180
max bends
12"
Minimum
FP1180

When it is not possible to meet the required vent terminal
clearances of 12" above grade level, a snorkel kit is recom-
mended. It allows installation depth down to 7" (178 mm)
below grade level. The 7" (178 mm) is measured from the
center of the horizontal vent pipe as it penetrates through
the wall.




If installing a snorkel, a minimum 12" vertical rise is neces-
sary. The maximum horizontal run with the 12” vertical pipe
is 36". This measurement is taken from the collar of the
fireplace (or transition elbow) to the face of the exterior wall.
See the Sidewall Venting Graph for extended horizontal
run if the vertical exceeds 12".
1. Establish vent hole through the wall.
2. Remove soil to a depth of approximately 16" below base
of snorkel. Install drain pipe. Install window well (not
supplied). Refill hole with 12" of coarse gravel leaving
a clearance of approximately 4" below snorkel. Figure
16
3. Install vent system.
4. Ensure a watertight seal is made around the vent pipe
coming through the wall.
5. Apply high temperature sealant caulking (supplied)
around the 5" and 8" snorkel collars.
6. Slide the snorkel into the vent pipes and secure to the
wall.
7. Level the soil so as to maintain a 4" clearance below
snorkel. Figure 16
FP2134
below grade install
FP2134
Figure 16 -
Below Grade Installation
Screws
Minimum
4" Clearance
Ground
Window
Well
Gravel
Drain
Foundation Wall
Firestop
12"
Minimum
If the foundation is recessed, use recess brackets (not
supplied) for securing lower portion of the snorkel. Fasten
brackets to wall first, then secure to snorkel with self drill-
ing #8 x 1/2" sheet metal screws. It will be necessary to
extend vent pipes out as far as the protruding wall face.
Figure 17