Monessen Hearth BDV500 Indoor Fireplace User Manual


 
30 54D0700
HI
LO
Electronic Valve
RED #2
GRAY #1
BLUE
YELLOW YELLOW
RED #2
WHITE #3
15’ Wall Switch Wire
B
LACK
WHITE
GREEN #4
BLACK #6
Switch
ON
OFF
RS
Secondary
24V
Transformer
YELLOW
WHITE
WHITE
GREEN
BLACK
BLACK
Primary - 120V
To Junction Box
Pilot Assembly
Spark
Sense
Ignition Module
EV1 EV2
24V #6
24V GND #5
PV #3
MV/PV #2
MV #1
GND (BURNER) #4
SENSE #8
SPARK #9
ELECTRICAL INSTALLATION
ELECTRONIC PILOT IGNITION WIRING
Do not connect 110-120 VAC to the
Remote Wall Switch. The appliance
will malfunction.
WARNING
REMOTE WALL SWITCH
Position the wall switch. Do not extend beyond the 15 feet of wire.
OPTIONAL DC REMOTE SYSTEMS
These instructions replace the section entitled Hearth Mount in the Millivolt hand held remote instructions supplied with
the remote.
1. Plug in remote connector wire to remote receiver.
2. Connect the wire terminal from the remote receiver. This replaces the 15' wall switch connection to the switch. See
Figure 37.
3. Mount remote control receiver at junction box (for your wall switch).
Figure 37 - Remote Wall Switch Wiring Diagram