Monessen Hearth BDV500 Indoor Fireplace User Manual


 
12 54D0700
Read all instructions completely and thoroughly before attempting installation. Failure
to do so could result in serious injury, property damage or loss of life. Operation of
improperly installed and maintained venting system could result in serious injury,
property damage or loss of life.
WARNING
Failure to follow these instructions will
void the warranty.
NOTICE
INSTALLATION PRECAUTIONS
Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system
for installation. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions.
Only a qualified installer/service person should install venting system. The installer must follow these safety rules:
Wear gloves and safety glasses for protection.
Use extreme caution when using ladders or when on rooftops.
Be aware of electrical wiring locations in walls and ceilings.
The following actions will void the warranty on your venting system:
Installation of any damaged venting component.
Unauthorized modification of the venting system.
Installation of any component part not manufactured or approved by MHS.
Installation other than permitted by these instructions.
FINISHING MATERIAL
NOTE: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to nal
nishing to avoid costly reconstruction.
INSTALLATION INFORMATION
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating of Zero) may be used to
cover the black surface of the appliance. A 300°F minimum adhesive may be used to attach facing materials to the black
surface. If joints between the finished wall and the fireplace surround are sealed, a 300°F minimum sealant material (General
Electric RTV103 or equivalent) must be used.
Never obstruct or modify the air inlet or outlet grills (louvers). This may create a
re hazard.
WARNING
VENT INSTALLATION