Monessen Hearth BDV500 Indoor Fireplace User Manual


 
54D0700 13
1"
3"
1"
1"
VENT INSTALLATION
This replace must be vented to the outside. The venting system must NEVER be
attached to a chimney serving a separate solid fuel burning appliance. Each gas
appliance must use a separate vent system. Do not use common vent systems.
WARNING
Horizontal sections of this vent system require
a minimum of 3" clearances to combustibles at
the top of the ue and 1" clearance at the sides
and bottom until the ue penetrates the outside
wall. A minimum 1" clearance all around the ue
is acceptable at this point of penetration.
Vertical sections of this vent system require a
minimum of 1" clearance to combustibles on all
sides of the pipe.
Figure 7 - Combustible Clearances for Vent Pipe
A Minimum of 3" Clearance
to the Top Is Required Along
Horizontal Length until Flue
Pipe Penetrates Outside Wall.
WARNING
A Minimum 1"
Clearance to
Combustibles
Permitted All
Around Flue
at Outside
Wall