NOTES : A point on the curve shows the reference point.
PKH30FK COOLING CAPACITY PKH30FK HEATING CAPACITY
PKH36FK COOLING CAPACITY PKH36FK HEATING CAPACITY
71
67
63
71
67
63
42
36
30
24
4.0
3.5
3.0
2.5
2.0
SHF=0.75
Total capacity(x10 Btu/h)
3
Total power consumption(kW)
Outdoor intake air DB temperature(¡F)
0 23 32 35 45 55 65 (67) 75 85 95 105 115
indoor intake air WB temperature(¡F)
indoor intake air WB temperature(¡F)
48
42
36
30
24
18
4.0
3.5
3.0
2.5
2.0
1.5
15 25 35 45 55 65
Outdoor intake air WB temperature(¡F)
indoor intake air DB temperature(¡F)
indoor intake air DB temperature(¡F)
Does not include booster heater(2.2kW)
65
70
75
75
70
65
Total capacity(x10 Btu/h)
3
Total power consumption(kW)
42
36
30
24
4.5
4.0
3.5
3.0
2.5
Total capacity(x10 Btu/h)
3
indoor intake air WB temperature(¡F)
SHF=0.71
Total power consumption(kW)
Outdoor intake air DB temperature(¡F)
indoor intake air WB temperature(¡F)
0 23 32 35 45 55 65 (67) 75 85 95 105 115
71
67
63
71
67
63
54
48
32
36
30
24
4.5
4.0
3.5
3.0
2.5
2.0
15 25 35 45 55 65
Outdoor intake air WB temperature(¡F)
indoor intake air DB temperature(¡F)
indoor intake air DB temperature(¡F)
Does not include booster heater(2.2kW)
65
70
75
75
70
65
Total capacity(x10 Btu/h)
3
Total power consumption(kW)
OC120--1.qxp 24/6/97 12:21 AM Page 9