Mitsubishi Electronics PUH18EK Air Conditioner User Manual


 
84
ORN 1
2
3
BRN
RED
3. TIMER ADAPTER
This adapter is needed for system control and for operation via external contacts. Adapter connection is described on page
57.
Part No. PAC-SA89TA-E
MITSUBISHI ELECTRIC
SET MONITOR
SMTWTFS
GET BACK
SET/MONITOR
BACK
AHEAD
ON
DAILY TIMER
BACK
SET BACK
ON OFF
OFF
DEGREE
SET BACK
WEERLY
TIMER
TODAY
CLOCK
AHEAD
Remote
controller
2-wire cable
5-wire cable
To indoor unit
Connector CN1 Connector CN1
Program
timer
2-3. How to connect program timer
(1) Install the program timer next to the remote controller the same way as the remote controller is installed.
(2) Connect the program timer and the remote controller with a 6-wire cable as shown in the figure below
NOTE:While the program timer is connected to the remote controller, the
24hour ON/OFF timer on the remote controller will not operate.
2-4 Names and functions
<PAC-SK65PT>
Mode selector button :Using this button to select ¨MONITOR¨ or
¨SET¨ mode.
¨MONITOR¨ :Indicates the current timer setting. All buttons
except will not work. This is the
normal status.
SET / MONITOR
¨SET¨ : ¨SET¨ is used to set the time, change the day of the
week, and program the daily and weekly timer.
Mode dispay
Current time
display
Current day
display
Weekly timer
display
Set back
display
Daily timer dislay
Clock adjustment button : Used to adjust the current time. Press
button to advance the time.
Each time the button is pressed the time
advances by 1 minute. Pressing continu-
ously advances 1 minute in a 0.5 second
interval. When the lower digit of minute
becomes 0 the indication advances in 10
minutes unit. button is used for
reversing the time. Each time the button
is pressed the time reverses by 1 minute.
Pressing continuously reverses the time
by 1 minute in a 0.5 second interval.
When the lower digit of minute becomes 0
the indication reverses in 10 minutes unit.
BACK
AHEAD
Day setting button : Used to adjust the day of the week.
Pressing button moves the day
light display in the order of S
MTW
BACK
Weekly timer button : Used to set the weekly timer.
Set back button : Used to set the set back amount.
Set back can bee set in the range of 1 to 48˚F
in 34˚F unit.
Daily timer button : Used to set the timer settings in units of 30
minutes.
NOTE : Display above
is only an exanple
OC120--3.qxp 24/6/97 1:05 AM Page 84