Models
Models Outdoor intake air DB temperature
(
˚F
)
PKH18FK
71
67
63
62.5
60
59
71
67
63
62.5
60
59
71
67
63
62.5
60
59
71
67
63
62.5
60
59
TC
21.0
19.5
18.2
18.1
17.2
16.8
27.9
26.1
24.3
24.1
23.0
22.5
34.9
32.6
30.4
30.2
28.8
28.2
39.8
37.1
34.7
34.4
32.8
32.2
SHC
14.4
16.0
17.4
15.5
15.1
14.5
16.1
18.5
20.5
18.0
17.6
17.0
21.5
24.5
26.9
23.8
23.2
22.4
23.0
26.3
29.3
25.8
25.1
24.3
TPC
1.56
1.52
1.49
1.49
1.47
1.46
2.05
2.01
1.97
1.96
1.94
1.93
2.72
2.66
2.60
2.59
2.57
2.56
3.00
2.93
2.87
2.86
2.82
2.81
TC
20.2
18.8
17.5
17.4
16.6
16.2
26.9
25.1
23.4
23.2
22.1
21.7
33.7
31.4
29.2
29.0
27.6
27.0
38.4
35.7
33.3
33.1
31.5
30.8
SHC
13.9
15.4
16.7
14.9
14.5
14.0
15.5
17.8
19.7
17.4
16.9
16.4
20.8
23.6
25.8
22.9
22.2
21.5
22.1
25.3
28.1
24.8
24.1
23.2
TPC
1.69
1.65
1.61
1.61
1.58
1.57
2.23
2.18
2.12
2.12
2.09
2.07
2.95
2.88
2.81
2.80
2.77
2.76
3.25
3.17
3.10
3.09
3.04
3.03
TC
19.4
18.0
16.8
16.6
15.8
15.5
25.8
24.0
22.4
22.2
21.1
20.7
32.3
30.0
27.9
27.7
26.3
25.7
36.8
34.2
31.9
31.6
30.1
29.5
SHC
13.3
14.8
16.0
14.3
13.8
13.4
14.9
17.0
18.9
16.6
16.2
15.6
19.9
22.5
24.6
21.9
21.2
20.4
21.2
24.3
26.9
23.7
23.0
22.3
TPC
1.84
1.79
1.74
1.74
1.70
1.69
2.43
2.36
2.30
2.29
2.25
2.24
3.21
3.12
3.04
3.03
2.99
2.98
3.54
3.44
3.35
3.34
3.28
3.26
TC
18.5
17.1
15.9
15.8
15.0
14.6
24.6
22.9
21.3
21.1
20.1
19.7
30.8
28.6
26.6
26.3
24.9
24.4
35.1
32.6
30.3
30.0
28.5
27.9
SHC
12.7
14.0
15.2
13.6
13.1
12.6
14.2
16.3
18.0
15.8
15.4
14.9
19.0
21.5
23.5
20.7
20.1
19.4
20.2
23.1
25.6
22.5
21.8
21.0
TPC
1.99
1.93
1.88
1.87
1.84
1.83
2.63
2.55
2.47
2.47
2.41
2.39
3.48
3.37
3.27
3.26
3.21
3.19
3.83
3.71
3.61
3.59
3.52
3.50
TC
17.6
16.3
15.1
15.0
14.2
13.9
23.4
21.7
20.1
19.9
18.9
18.5
29.3
27.1
25.1
24.9
23.5
22.9
33.4
30.9
28.7
28.4
26.9
26.4
SHC
12.1
13.4
14.4
12.9
12.4
12.0
13.5
15.4
17.0
14.9
14.5
14.0
18.1
20.3
22.2
19.6
18.9
18.2
19.3
21.9
24.2
21.3
20.6
19.9
TPC
2.15
2.07
2.01
2.00
1.96
1.94
2.84
2.73
2.65
2.64
2.58
2.56
3.75
3.61
3.50
3.49
3.43
3.41
4.13
3.98
3.86
3.85
3.76
3.73
IWB
(
˚F
)
DB 75¡F (50%RH)
DB 72¡F (50%RH)
DB 70¡F (50%RH)
DB 75¡F (50%RH)
DB 72¡F (50%RH)
DB 70¡F (50%RH)
DB 75¡F (50%RH)
DB 72¡F (50%RH)
DB 70¡F (50%RH)
DB 75¡F (50%RH)
DB 72¡F (50%RH)
DB 70¡F (50%RH)
75 85 95 105 115
710
0.16
Airflow
(
CFM
)
B.F
PKH24FK
710
0.16
PKH30FK
990
0.15
PKH36FK
990
0.14
Notes 1. B.F. : Bypass Factor, IWB : Intake air wet-bulb temperature
TC : Total Capacity (x10
3
Btu/h), SHC : Sensible Heat Capacity (x10
3
Btu/h)
TPC : Total Power Consumption (kW)
2. SHC is based on 80˚FDB of indoor intake air temperature.
3. Cooling capacity correction factors and Refrigerant piping length (one way) range.
MODEL
Refrigerant piping length
(
one way
)
PKH18FK
PKH24FK
PKH30FK
PKH36FK
1.0
1.0
1.0
1.0
25ft
0.992
0.981
0.981
0.981
40ft
0.983
0.968
0.968
0.968
55ft
0.978
0.952
0.952
0.952
70ft
0.966
0.940
0.940
0.940
85ft
0.959
0.925
0.925
0.925
100ft
0.950
0.913
0.913
0.913
115ft
0.945
0.900
0.900
0.900
130ft
0.886
0.886
0.886
150ft
0.874
0.874
0.874
164ft
3
DATA
MODELS : PKH18/24/30/36FK
1. PERFORMANS DATA
1) COOLING CAPACITY