14
8. Function Selection
[4]–3. Mode selection setting
(1) Remote controller main/sub setting
To switch the setting, press the [ ON/OFF] button
D
.
1
Main: The controller will be the main controller.
2
Sub: The controller will be the sub controller.
(2) Use of clock setting
To switch the setting, press the [ ON/OFF] button
D
.
1
ON: The clock function can be used.
2
OFF: The clock function cannot be used.
(3) Timer function setting
To switch the setting, press the [
ON/OFF] button
D
(Choose
one of the following.).
1
WEEKLY TIMER (initial setting value):
The weekly timer can be used.
2
AUTO OFF TIMER:
The auto off timer can be used.
3
SIMPLE TIMER:
The simple timer can be used.
4
TIMER MODE OFF:
The timer mode cannot be used.
* When the use of clock setting is OFF, the “WEEKLY TIMER” can-
not be used.
(4) Contact number setting for error situation
To switch the setting, press the [ ON/OFF] button
D
.
1
CALL OFF:
The set contact numbers are not displayed in case of error.
2
CALL **** *** ****:
The set contact numbers are displayed in case of error.
CALL_:
The contact number can be set when the display is as shown
above.
Setting the contact numbers
To set the contact numbers, follow the following procedures.
Move the blinking cursor to set numbers. Press the [ TEMP.
( ) and ( )] button
F
to move the cursor to the right (left).
Press the [ CLOCK ( ) and ( )] button
C
to set the num-
bers.
[4]–4. Display change setting
(1) Temperature display °C/°F setting
To switch the setting, press the [ ON/OFF] button
D
.
1
°C: The temperature unit °C is used.
2
°F: The temperature unit °F is used.
(2) Room air temperature display setting
To switch the setting, press the [ ON/OFF] button
D
.
1
ON : The room air temperature is displayed.
2
OFF: The room air temperature is not displayed.
(3) Automatic cooling/heating display setting
To switch the setting, press the [ ON/OFF] button
D
.
1
ON:
One of “Automatic cooling” and “Automatic heating” is dis-
played under the automatic mode is running.
2
OFF:
Only “Automatic” is displayed under the automatic mode.
[Detailed setting]
[4]–1. CHANGE LANGUAGE setting
The language that appears on the dot display can be selected.
Press the [ MENU] button
G
to change the language.
1
English (GB),
2
German (D),
3
Spanish (E),
4
Russian (RU),
5
Italian (I),
6
Chinese (CH),
7
French (F),
8
Japanese (JP)
Refer to the dot display table.
[4]–2. Function limit
(1) Operation function limit setting (operation lock)
To switch the setting, press the [
ON/OFF] button .
1
no1 :Operation lock setting is made on all buttons other than
the [ ON/OFF] button.
2
no2 :Operation lock setting is made on all buttons.
3
OFF (Initial setting value): Operation lock setting is not made.
* To make the operation lock setting valid on the normal screen, it
is necessary to press buttons (Press and hold down the [FILTER]
and [ ON/OFF] buttons at the same time for two seconds.) on
the normal screen after the above setting is made.
(2) Use of automatic mode setting
When the remote controller is connected to the unit that has auto-
matic operation mode, the following settings can be made.
To switch the setting, press the [ ON/OFF] button
D
.
1
ON (Initial setting value):
The automatic mode is displayed when the operation mode is
selected.
2
OFF:
The automatic mode is not displayed when the operation
mode is selected.
(3) Temperature range limit setting
After this setting is made, the temperature can be changed within
the set range.
To switch the setting, press the [ ON/OFF] button
D
.
1
LIMIT TEMP COOL MODE:
The temperature range can be changed on cooling/dry mode.
2
LIMIT TEMP HEAT MODE:
The temperature range can be changed on heating mode.
3
LIMIT TEMP AUTO MODE:
The temperature range can be changed on automatic mode.
4
OFF (initial setting): The temperature range limit is not active.
* When the setting, other than OFF, is made, the temperature
range limit setting on cooling, heating and automatic mode is
made at the same time. However, the range cannot be limited
when the set temperature range has not changed.
To increase or decrease the temperature, press the
[ TEMP. ( ) or ( )] button
F
.
To switch the upper limit setting and the lower limit setting, press
the [ ] button
H
. The selected setting will blink and the tem-
perature can be set.
• Settable range
Cooling/Dry mode:
Lower limit: 19°C~30°C, 67°F~87°F
Upper limit: 30°C~19°C, 87°F~67°F
Heating mode:
Lower limit: 17°C~28°C, 63°F~83°F
Upper limit: 28°C~17°C, 83°F~63°F
Automatic mode:
Lower limit: 19°C~28°C, 67°F~83°F
Upper limit: 28°C~19°C, 83°F~67°F