Mitsubishi Electronics MSH-18NV Air Conditioner User Manual


 
New publication, effective Sep. 1997
Specifications subject to change without notice.
CC
Copyright 1997 MITSUBISHI ELECTRIC ENGINIEERING CO.,LTD
Issued in Sep. 1997. No.OB207 646
Printed in Japan
HEAD OFFICE MITSUBISHI DENKI BLDG.MARUNOUCHI TOKYO100 TELEX J24532 CABLE MELCO TOKYO
9.52 (3/8)
12.7 (1/2)
15.88 (5/8)
Pipe length
Cross-section
Part No.Model
A-Gas B-Liquid
Pipe size O.D mm (in.)
Insulation
DC
Additional
refrigerant
charge
R-22(g)
E1
E1
E2
E2
E2
E1
E1
E2
E3
E1
E2
MSH-07NV-
MSH-09NV-
MSH-07NV-
MSH-09NV-
MSH-12NV-
MSH-12NV-
MSH-18NV-
MSH-18NV-
MSH-18NV-
MSH-24NV-
MSH-24NV-
MAC-440PI
MAC-441PI
MAC-442PI
MAC-443PI
MAC-660PI
MAC-661PI
MAC-662PI
MAC-663PI
MAC-664PI
MAC-670PI
MAC-671PI
MAC-672PI
MAC-673PI
MAC-674PI
MAC-860PIE
MAC-861PIE
MAC-862PIE
MAC-863PIE
MAC-864PIE
3m
5m
7m
10m
3m
5m
7m
10m
15m
3m
5m
7m
10m
15m
3m
5m
7m
10m
15m
6.35 (1/4)
9.52 (3/8)
27
31
21
27
0
150
0
150
400
0
150
400
0
195
520
2. AIR CLEANING FILTER
AIR CLEANING FILTER removes fine dust of 0.01 micron from air by means of static electricity.
Normal life of AIR CLEANING FILTER is 3 months. However, when it becomes dirty, replace it as soon as possible.
Clogged AIR CLEANING FILTER may reduce the air conditioner capacity or cause frost on the air outlet.
DO NOT reuse AIR CLEANING FILTER even if it is washed.
DO NOT remove or attach AIR CLEANING FILTER during unit operation.
3. DEODORIZING FILTER
DEODORIZING FILTER removes ammonia and hydrogen sulphide emitted from tobacco, and odors of pets.
Clean DEODORIZING FILTER every two weeks. If the filter is particularly dirty, clean the filter more often.
For cleaning, soak the filter in warm water for a while, and then wash and rinse it. Dry the filter in the shade thoroughly.
When the filter color is still dark even after cleaning, replace the filter with a new one.
Replace the filter at least once a year.
DEODORIZING FILTER and AIR CLEANING FILTER can be attached on either side.
Model
Part No.
MAC-1000FT
MAC-1100FT
E1
E2
MSH-07NV-
MSH-09NV-
MSH-12NV-
MSH-18NV-
MSH-24NV-
MSH-18NV-
MSH-07NV-
MSH-09NV-
MSH-12NV-
MSH-24NV-
MSH-18NV-
E1
E1
E1
E1
E2
E3
E2
E2
E2
Model
Part No.
E1
E2
MSH-07NV-
MSH-09NV-
MSH-12NV-
MSH-18NV-
MSH-24NV-
MSH-18NV-
MSH-07NV-
MSH-09NV-
MSH-12NV-
MSH-24NV-
MSH-18NV-
E1
E1
E1
E1
E3
E2
E2
E2
E2
MAC-1500DF
MAC-1600DF
1. REFRIGERANT PIPES
The air conditioner has flared connections its indoor and outdoor sides.
Please use the optional extension pipe as follows.
13 OPTIONAL PARTS
OB207t-3qxp 25/9/97 9:11 PM Page 80