Mitsubishi Electronics MSH-18NV Air Conditioner User Manual


 
33
MICROPROCESSOR CONTROL
8
Once the controls are set, the same operation mode can be
repeated by simply turning the OPERATE/STOP button ON.
Indoor unit receives the signal with a beep tone.
When the system turns off, 3-minute time delay will operate to
protect system from overload and compressor will not restart
for 3 minutes.
8-1. “I FEEL CONTROL” ( ) OPERATION
(1) Press OPERATE/STOP button on the remote controller.
OPERATION INDICATOR lamp of the indoor unit will turn
on with a beep tone.
(2) Press OPERATION SELECT button to set “I FEEL CON-
TROL”( ). Then a beep tone is heard.
(3) The operation mode is determined by the initial room
temperature at start-up of the operation.
Wireless remote controller
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
Once the mode is fixed, the mode will not change by
room temperature afterwards.
Under the ON-TIMER ( ) operation, mode is deter-
mined according to the room temperature as the opera-
tion starts.
When the system is stopped with the OPERATE/STOP
button on the remote controller, and restarted within 2
hours in “I FEEL CONTROL” ( ) mode, the system
operates in previous mode automatically regardless of
the room temperature.
Mode
COOL mode of
"I FEEL CONTROL"
DRY mode of
"I FEEL CONTROL"
HEAT mode of
"I FEEL CONTROL"
Initial room temperature
more than 25:
23: to 25:
less than 23:
Example
Previous operation
COOL mode of
“I FEEL CONTROL”
or COOL mode
When the system is restarted after 2 hours, the operation
mode is determined by the initial room temperature at
start-up of the operation.
Restart
COOL mode of
“I FEEL CONTROL”
Restart
COOL or DRY or
HEAT mode of “I FEEL
CONTROL” that deter-
mined by initial room
temperature at start-up
of the operation.
INDOOR UNIT DISPLAY SECTION
MSH-07NV - MSH-09NV - MSH-12NV -
MSH-18NV - MSH-24NV -
MSH-07NV - MSH-09NV - MSH-12NV -
MSH-18NV - MSH-24NV - MSH-18NV -
E3E2E2
E2E2E2
E1E1
E1E1E1
OB207t-2qxp 25/9/97 8:54 PM Page 33