Mitsubishi Electronics MSH-18NV Air Conditioner User Manual


 
27
Models
Piping size O.D : mm Length of connecting pipe : m
Refrigerant piping
Max. length : m
A
10
15
Indoor unit
0.43
Gas
9.52
12.7
15.88
Liquid
6.35
9.52
Outdoor unit
0
MSH-07NV - E1
MSH-09NV - E1
MSH-07NV - E2
MSH-09NV - E2
MSH-12NV - E1
MSH-12NV - E2
MSH-18NV - E1
MSH-18NV - E2
MSH-18NV - E3
MSH-24NV - E1
MSH-24NV - E2
Models
Refrigerant piping length (one way)
Outdoor unit precharged
(up to 7m)
850
1150
1800
15m
400
7m
0
10m
150
MSH-07NV - E1
MSH-09NV - E1
MSH-07NV - E2
MSH-09NV - E2
MSH-12NV -
E1
MSH-12NV -
E2
MSH-18NV -
E1
MSH-18NV -
E2
MSH-18NV -
E3
MAX. HEIGHT DIFFERENCE
ADDITIONAL REFRIGERANT CHARGE(R-22 : g)
MAX. REFRIGERANT PIPING LENGTH
Calculation : Xg=50g/m (A-7)m
Calculation : Xg=65g/m (A-7)m
Models
Outdoor unit precharged
(up to 7m)
2400
Refrigerant piping length (one way)
15m
520
7m
0
10m
195
MSH-24NV -
E1
MSH-24NV -
E2
OB207t-1qxp 25/9/97 8:53 PM Page 27