4.2
THE SC2800
BASE STATION
1. PANIC
When pressed, this red button initiates an
immediate alarm.
2. ARM HOME
Alarm function when being at home. Only door
and window sensors (no motion sensors) are
activated.
3. ARM AWAY
All sensors are activated.
4. BYPASS
When you want to arm the system and one of the
sensors is reporting a problem (e.g. window is still
open, battery low, etc.), you can choose to arm
the system without activating this particular
sensor. As long as you can hear the dual error tone
error, you have the option to press the “bypass”
button and arm the system again. The zone
indicator of that sensor is now flashing rapidly.
Once the error condition is corrected (e.g.
window closed), the bypass will be automatically
removed and the sensor becomes part of the
total system again.
5. DISARM
Disarms the system after entering your personal
identification code (PIN).
6. SYSTEM INDICATORS
RECORD – Lights when during recording and
playing the personal security message.
JAMMING- Indication that a strong interfering
signal is detected.
ARM- Lights when the system in armed.
BATTERY LOW- Indication that the back up battery
of the base station needs to be replaced.
POWER- Indication for proper operation of the
PS500. Lights during normal operation.
7. KEYBOARD
To program and operate the security system.
8. UNIT ON/UNIT OFF
For operating Marmitek X-10 Home Automation
Modules (like LM12 Lamp Module). Enter the unit
code of the module on the keyboard. Then use
this key to switch this module on or off.
9. BRIGHT/DIM
For controlling the brightness of lights connected
to a specific lamp module. Enter the unit code of
the module on the keyboard and then use this key
to brighten or dim the lights.
10. ALL LIGHTS ON/OFF
To switch on all lamp modules in the system or to
switch off all modules (lamp and appliance
modules), regardless the address.
11. MICROPHONE
Very sensitive microphone for:
• recording a personalised alarm message
• “listen-in” to the protected premises via the
telephone line during an alarm situation
12. RUN 1, RUN 2, INSTALL, THERM SWITCH
RUN 1 – For normal alarm operation.
RUN 2 – For normal alarm operation. When in
disarmed mode, the base station will give a
pleasant sounding tone when a door or window is
opened (access control).
INSTALL – Position for installing sensors and for
changing system settings.
THERM - For use with Marmitek X-10 Wireless
Thermostats. Thermostat functions are
described in the manual of the thermostat.
6 MARMITEK
1
2
3
4
5
7
11
6
10
18 19 20 21 22
23
9
12
16
14
15
13
17
8