Marmitek MS9970 Home Security System User Manual


 
At the front of the modules, you’ll find 2 code
switches: Unit Code (1 through 16) and House
Code (A through O). Take care that when you are
using the modules in combination with the
security system, the House Code of the base
station and lamp module are the same. You now
can control lamp modules individually with the
SH624 remote control keys corresponding to the
unit code: 1 through 8 or 9 through 16.
Beside the security function, the base station is
also a Home Automation controller using the so-
called Marmitek X-10 protocol. In combination
with Marmitek X-10 modules, you can remotely
control lights and appliances.
Also in case of an alarm, this technology is being
used to control lights and external sirens. As such,
lights connected to the lamp module will be
switched on and off (flash) during an alarm
situation for a time period of 4 minutes. After
these 4 minutes, they will remain on at full
brightness (refer to 6.8). You can expand the
system with multiple lamp modules.
For more information about the many options of
the Marmitek X-10 system, contact the web site
(www.marmitek.com) or your dealer.
12 MARMITEK
The Marmitek Security System allows you to also
connect wired (non wireless) sensors to the
SC2800 base station. This allows the use of the
Marmitek Security System in a number of special
applications under special circumstances. You
now can e.g. still protect a door or window out of
the radio range of base station by using a wired
magnetic contact. You can now also use third
party -non Marmitek- sensors in combination with
the system. Examples of such sensors are: smoke
The sensor has to be placed on the window glass.
The glass break sensor reacts to the frequency of
breaking glass. Position the glass break sensor on
windows of which you suspect to be used during
a break in into the premises. Place the sensor in
such a way that the antenna is positioned in
vertical direction. Do not place the glass break
sensor on windowpanes which are constantly
vibrating (e.g. caused by a window fan). Further,
the GB10 has a light sensor. At dusk, a signal is
transmitted to the base station to start the
Lifestyle program.
detectors with relay output, level or temperature
sensors (freezer, etc.), flood detectors or motion
sensors for special applications.
To connect these sensors, use the special input
jack on the back of the base station. You can
connect any so-called NC (normally closed)
contact by means of the special cable supplied
with the system. You can connect multiple wired
sensors to this input. These sensors, when
connected, are automatically programmed on
zone16. In case the contact opens, the security
system will respond in the way it is programmed,
in the same way as for the other sensors (so
including telephone dialler, etc.). For erasing a
programmed zone, refer to 5.9.
4.8 PLACING OTHER (WIRED)
SENSORS
4.9 PLACING A GLASS BREAK SENSOR
(OPTION)