mini HE --- Installation & Servicing
Ta b l e 1 --- B o il e r D a t a
mini HE C24 mini HE C28 mini HE C32
Gas supply type & connection II
2H3P
G20 20mbar, G31 37mbar, 22 mm copper
Inlet / Outlet connection --- Domestic Hot Water 15 mm copper
Flow & return connection --- Central Heating 22 mm copper
Flue terminal diameter mm (in.) 100 (4)
AverageFlueTemp.---MassFlowRate Deg C | g/s 90 18.8 90 21.1 90 21.5
Max working pressure (sealed system) bar (lb/in
2
) 3.0 (43.5)
Max DHW water inlet pressure bar (lb/in
2
) 10.0 (145.0)
Min DHW water inlet pressure bar (lb/in
2
) 0.3 (4.4)
Electrical supply 230 Vac 50 Hz
Max power consumption W 140 150 150
External fuse rating 3A
Internal fuse rating F1---F2 3.15 AF
Water content --- CH litre (gal.) 2.1 (0.46) 2.2 (0.48) 2.2 (0.48)
Water content --- DHW litre (gal.) 0.2 (0.044)
Dry weight kg (lb.) 42.5 (93.7) 44.5 (98.1) 44.5 (98.1)
Size: Height / Width / Depth mm (in.) 803 (31 5/8”) / 400 (15 3/4”) / 345 (13 9/16”)
Lift weight kg (lb.) 37.5 (82.7) 39.5 (87.1) 39.5 (87.1)
Ta b l e 2 --- Pe r f or m a nc e D a t a --- C e n t ra l H ea t i n g
mini HE C24 mini HE C28 mini HE C3 2
Max Min Max Min Max Min
Burner pressure (Hot) G20
G31
mbar
(in.w.g.)
10.8 (4.3)
35.5 (14.2)
1.5 (0.6)
7.7 (3.1)
10.0 (4.0)
36.0 (14.4)
1.6 (0.6)
7.7 (3.1)
13.0 (5.2)
36.0 (14.4)
2.7 (1.1)
7.3 (2.9)
Input based on nett CV kW (btu/h) 25.0 (85 295) 11.0 (37 530) 29.0 (98 942) 13.0 (44 353) 33.3 (113 620) 15.7 (53 568)
Input based on gross C V kW (btu/h) 27.7 ( 94 516) 12.2 (41 628) 32.2 (109 871) 14.4 (49 135) 37.0 (126 244) 17.4 (59 368)
Output Non Condensing G20
G31
kW (btu/h) 24.6 ( 83 973)
23.7 (80 894)
10.2 (34 936)
10.2 (34 936)
28.3 (96 488)
27.4 (93 599)
12.1 (41 284)
12.1 (41 284)
32.2 (109 866)
32.2 (109 866)
15.0 (51 180)
15.0 (51 180)
Output Condensing G20
G31
kW (btu/h) 26.6 ( 90 754)
26.6 (90 754)
11.1 (37 871)
10.8 (36 997)
30.7 (104 602)
30.7 (104 602)
13.2 (44 965)
12.9 (44 016)
34.4 (117 374)
34.4 (117 374)
15.6 (53 227)
15.6 (53 227)
Gas consumption (Hot) G20
G31
l/s (ft
3
/h)
l/s
0.72 (91.5)
0.30
0.31 (39.5)
0.13
0.83 (105.5)
0.34
0.37 (47.0)
0.14
0.95 (121.0)
0.39
0.45 (57.2)
0.18
Seasonal efficiency* G20
G31
(SEDBUK)
%
Band B 87.7
Band B 87.0
Band B 87.6
Band B 87.1
Band B 86.8
Band B 88.8
NOx classification Class 2
*The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings.
The test data from which it has been c alculated have been certified by a notified body.
Ta b l e 3 --- Pe r f or m a nc e D a t a --- D o me s t ic H ot W a t e r
mini HE C24 mini HE C28 mini HE C32
Maximum
Burner pressure (Hot) G20
G31
mbar
(in.w.g.)
10.8 (4.3)
35.5 (14.2)
10.0 (4.0)
36.0 (14.4)
13.0 (5.2)
36.0 (14.4)
Input based on nett CV kW (btu/h) 25.0 (85 295) 29.0 (98 942) 33.3 (113 620)
Input based on gross C V kW (btu/h) 27.7 (94 516) 32.2 (109 871) 37.0 (126 244)
Output Non Condensing G20
G31
kW (btu/h) 24.6 (83 973)
23.7 (80 894)
28.3 (96 488)
27.4 (93 599)
32.2 (109 866)
32.2 (109 866)
Output Condensing G20
G31
kW (btu/h) 26.6 (90 754)
26.6 (90 754)
30.7 (104 602)
30.7 (104 602)
34.4 (117 374)
34.4 (117 374)
Gas consumption (Hot) G20
G31
l/s (ft
3
/h)
l/s
0.72 (91.5)
0.30
0.83 (105.5)
0.34
0.95 (121.0)
0.39
Flow 35 ûCtemp.rise l/m (gpm) 10.0 (2.2) 11.7 (2.6) 13.1 (2.9)
Domestic hot water specific rate l/m ( gpm) 11.9 (2.6) 13.9 (3.1) 14.6 (3.3)
Note: the gas consumption is calculated using a calorific
value of 38.7 MJ/m
3
(1038 Btu/ft
3
) gross or 34.9 MJ/m
3
(935
Btu/ft
3
) nett.
To obtain the gas consumption at different calorific value: ---
a. FOR L/S --- divide the gross heat input (kW) by the gross
C.V. of the gas (MJ/m
3
)
b. FOR FT
3
/H --- divide the gross heat input (Btu/h) by the
gross C.V. of the gas (Btu/ft
3
)
Key to Symbols:
IE = Ireland, GB = United Kingdom (Countr i es of destination)
PMS = Maximum operating pressure of water
C
12
C
32
C
52
= a room sealed appliance designed for
connection via concentric ducts to a horizontal or vertical
terminal or twin flue system.
II
2H3P
= appliance designed for use on 2nd family gas group
H or 3rd family gas group 3P
CAUTION. To avoid the possibility of inju ry during the i nstallation, servicing or cleaning
of this appliance care should be taken handling edges of sheet steel components.