INSTALLATION
mini HE --- Installation & Servicing
20
18 FITTING THE OPTIONAL ROOF FLUE
KIT (Flat or Pitched)
Note.
A flat or pitched roof flashing plate (not supplied) is required
before proceeding with the installation of this kit.
This kit is suitable for both flat and pitched roof terminations,
using a concentric flue to run vertically from the top of the
boiler and terminating above roof level.
Connection to the top of the boiler is made using a separately
supplied vertical connector.
WEATHER PROOFING
Where the flue passes through the roof line an adequate seal
must be made. This is achieved by using either:
--- Flat roof weather collar
--- Universal weather collar.
ACCESSORIES
Flue Duct Extension Kits are avail able for flue lengths
extending beyond 1m. These packs contain 1m extension
ducts and may be cut to the desired length.
If the offset vertical option is used an elbow Kit is required. For
a full accessories list refer to Frame 9, Optional Extras.
19 ROOF FLUE KIT
CONTENTS/OPTIONS
A Flue assembly with terminal
B Flue seal collar
C3,5X13screw
D Pitched roof tile/flat roof tile weather collar
E Vertical connector (80/125)
F Retention screws
G Roof flue extension duct kit (80/125)
H90û elbow kit (80/125)
I45û elbow kit (80/125)
I
H
G
F
E
DA
C
B
INSTALLATION