6 Features & Specifications
© Travis Industries 100-01163 4041129
Installation Options:
• Masonry Fireplace Insert
WARNING: Do not install this fireplace insert into a
factory-built metal (Z.C.) fireplace.
Features:
• EPA Phase II Approved
• 3.1 Cubic Foot Firebox Volume
• Single Operating Control
• Accepts Logs Up to 24" Long
• Steel Plate Construction (5/16" & 3/16")
• Heavy Duty Refractory Firebrick
• High-Tech Blower
Heating Specifications:
Approximate Maximum Heating Capacity (in square feet)* 1,200 to 2,250
Maximum BTU's per Hour (Cord Wood Calculation) 74,300
Overall Efficiency (Oregon Method) 70 %
Maximum Burn Time Up to 12 Hours
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside
temperature. It is also affected by the quality and moisture level of the fuel.
Dimensions:
21-3/4"
Measure side clearances
from the side of the insert.
Electrical Line (may
be attached to the
opposite side)
29-1/4"
5-5/8"
Fireplace Opening
15-3/4"
Faceplate
4-3/4"
Measure top
clearances from
the top plate.
43-3/4"
Weight = 470 Lbs.
20-1/4"
6" Diameter Flue
Measure front clearances
from the faceplate.
Figure 1
Emissions:
2.6 Grams Per Hour (EPA Phase II Approved) – Tests conducted by E.E.S.P.C.