Lopi Freedom Bay Fireplace Insert Indoor Fireplace User Manual


 
Operating Your Appliance 17
© Travis Industries 100-01163 4041129
Adjusting the Burn Rate
Use the air control slider to control the burn rate of the stove. See the illustration below for details.
Low Burn
(air control closed)
High Burn
(air control open)
Use the air control to
change the burn rate.
Approximate Air Control Settings:
Overnight Burn Fully out to 9/32" open
Medium Burn 9/32" to 5/16" open
Medium High Burn 5/16" to 7/16" open
High Burn 7/16" open to fully pushed in
The air control becomes hot during operation - use gloves or a tool to prevent burns.
The air control may take several minutes to influence the burn rate. When making adjustments, you
may wish to let the stove burn for 10 minutes to gauge performance.
Ash Removal
ASHES
Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes
should be placed on a noncombustible floor or on the ground, away from all combustible
materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally
dispersed, they should be retained in the closed container until all cinders have thoroughly
cooled.