Lopi DVL Insert EF II Indoor Fireplace User Manual


 
Installation (for qualified installers only) 7
© Travis Industries 4060111 100-01174
Installation Warnings
Failure to follow all of the requirements may result in property damage, bodily
injury, or even death.
This heater must be installed by a qualified installer who has gone through a
training program for the installation of direct vent gas appliances.
This appliance must be installed in accordance with all local codes, if any; if not,
follow ANSI Z223.1 and NFPA 54(88).
In Manufactured or Mobile Homes must conform with Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a
standard is not applicable, the Standard for Manufactured Home Installations,
ANSI/NCSBCS A225.1. This appliance may be installed in Manufactured Housing
only after the home is site located.
The heater is designed to operate on natural gas, or propane (LP).
All exhaust gases must be vented outside the structure of the living-area.
Combustion air is drawn from outside the living-area structure.
Notify your insurance company before hooking up this heater.
The requirements listed below are divided into sections. All requirements must
be met simultaneously. The order of installation is not rigid – the qualified
installer should follow the procedure best suited for the installation.
Packing List
Top Convection Deflector (with screws)
Propane Conversion Kit
Log Set
Glass Latch Key (to un-latch glass frame)
"Fireplace Altered" tag (attach to the fireplace)
FPX Face Brackets (see pg. 11 for details)
Additional Items Required
Faceplate
6-5/8" to 3" & 4" Co-Linear Adapter - with flashing (Travis part # 98900124)
3" and 4" Diameter Gas Liner
Direct Vent Cap (Simpson Duravent Part # 991)
Gas Line Equipment (shutoff valve, pipe, etc.)
Items Packed with the Face
Face with attachment hardware and cove covers (if necessary)
Face Installation Instructions
Order of Installation
1 Install the Top Convection Deflector (see page 8).
2 If the heater is to use propane, install the propane conversion kit (see page 36).
3 Install gas line into the fireplace (do not connect to unit).
4 Position the heater.
5 Connect the gas line and gas vent to the appliance.
6 Install the optional surround panels and trim. Attach the on/off switch.
7 Follow the instructions under "Finalizing the Installation" on page 24.