Lopi DVL Insert EF II Indoor Fireplace User Manual


 
20 Finalizing the Installation
© Travis Industries 4060111 100-01174
Glass Frame Removal and Installation
Warning: The appliance must be completely cool before removing the glass.
Warning: Do not strike or slam the glass.
Note: If using a Victorian Lace or Bungalow face, attach the arch covers after installing the glass.
Open the four latches holding the glass
frame in place (start with the two below
the glass) - follow the directions shown
to the right.
a
Twist 1/4 turn.
The spring pin will
disengage from the
latch bracket,
opening the latch.
Latch Bracket
Insert the 1/4 key
into the spring
pin.
Glass
Top of
Firebox
Spring Pin
Glass Frame
Lift the glass frame up
and pull it forward to
remove.
NOTE:
You may need to lift the
glass frame while re-
attaching.
b
Re-Attaching the Glass Frame:
a) Hang the glass frame on the firebox.
b) While holding in place, attach the upper latches
(follow the instructions to the right in reverse).
c) Lift the glass frame slightly and attach the lower latches.
NOTE:
Replace the cove
covers for those faces
using them.