Lopi DVL Insert EF II Indoor Fireplace User Manual


 
6 Features and Specifications
© Travis Industries 4060111 100-01174
Features
Works During Power Outages (millivolt system)
High Efficiency
Optional Thermostat or Remote Control
Ember Fyre™ Burner for "Wood Fire" Look
Quiet Blower for Effective Heat Distribution
Convenient Operating Controls
Variable-Rate Heat Output
Low Maintenance
Installation Options
Residential or Mobile Home
Fireplace Insert
Masonry or Factory Built (Metal) Wood-
Burning Fireplace
Heating Specifications
Natural Gas Propane
Approximate Heating Capacity (in square feet)* 600 to 2,000 600 to 2,000
Maximum BTU Input Per Hour 40,000 40,000
Minimum BTU Output on Low 20,300 19,700
Steady State Efficiency** (with blowers on) Up to 79.3 % Up to 81.2 %
AFUE (Annual Fuel Utilization Efficiency) Up to 71.7 % Up to 73.4 %
* Heating capacity will vary with floor plan, insulation, and outside temperature.
** Efficiency rating is a product of thermal efficiency rating determined under continuous
operation independent of installed system.
Dimensions
40"* 4x6 Rect. Panels
44-3/16"* 8x10 Arch/Rect. Panels
48-3/16"* 10x13 Rect. Panels
* Includes trim
NOTE: on older style panels the 3/8" standoffs
are no longer required and may be bent back.
20"
See the section "Vent Requirements"
for vent location.
14-1/2"*
1-1/4"*
29"* 4x6
Rect. Panels
33-3/8"* 8x10
Arch/Rect. Panels
36-3/8"* 10x13
Rect. Panels
31-1/2"
23-3/4"