LG Electronics LAN181CNW, LAU181CNW, LA180CPI, LA180CPO Air Conditioner User Manual


 
38 Room Air Conditioner
Installation
CAUTION
CAUTION
Air
Conditioner
Circuit Breaker
Use a circuit
breaker or time
delay fuse.
Main power source
If a power plug is not to be used, provide a circuit breaker between power source and the
unit as shown below.
3) Connect the cable to the indoor unit
1. Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
Ensure that the color of the wires of outdoor unit
and the terminal No. are the same as those of
indoor unit respectively.
(Refer to Wiring diagram on page16.)
Be sure to refer to the wiring diagram label
inside the grille and carry out the correct
field wiring.
Wrong wiring can cause the unit to misoperate
to result in a fire hazard.
Check local electrical codes and any specified
wiring instructions or limitations.
WARNING
Connecting cable