30 Room Air Conditioner
Installation
4) How to fix installation plate
The wall you select should be strong and solid enough
to prevent vibration
Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a concrete
wall, use anchor bolts.
■ Mount the installation plate horizontally by aligning
the centerline using a level.
5) Preparing work for installation
1. Drill a hole in the wall
• Drill the piping hole with a ø50mm hole core drill.
Drill the piping hole at either the right or the left with
the hole slightly slanted to the outdoor side.
Installation Plate
240mm
(19.4")
240mm
(19.4")
60mm
(2.4")
60mm
(2.4")
Type "A" screw
Ø 70mm
(2.8")
Ø 70mm
(2.8")
5-7mm
(0.2~0.3")
Indoor
WALL
Outdoor
Measure the wall and mark the centerline. It is also
important to use caution concerning the location of
the installation plate-routing of the wiring to power
outlets is through the walls typically. Drilling the hole
through the wall for piping connections must be
done safely.
B
A