Installation
3) Connection of the pipes-Outdoor
1. Align the center of the pipings and sufficiently
tighten the flare nut by hand.
2. Finally, tighten the flare nut with torque wrench
until the wrench clicks.
When tightening the flare nut with torque wrench,
ensure the direction for tightening follows the arrow on
the wrench.
Installation Information (For right piping)
Good case
For right piping. Follow the instruction below.
Press on the upper side of clamp and
unfold the tubing to downward slowly.
Bad case
Following bending type from left to right could cause
problem of pipe damage.
CAUTION
mm inch Kgf
.
cm
Ø6.35 1/4 180~250
Ø9.52 3/8 340~420
Ø12.7 1/2 550~660
Ø15.88 5/8 630~820
Ø19.05 3/4 990~1210
Outside diameter
Torque
Outdoor unit
Liquid side piping
(Smaller diameter)
Gas side
piping
(Bigger
diameter)
Torque wrench