Lennox International Inc. PS40 Stove User Manual


 
10
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Venting
This stove is approved for venting with Type L and Type PL pellet vent
pipe listed to UL 641 and ULC S609. We recommend the use of venting
products manufactured by Security™ Chimneys International. Single wall
pipe cannot be used with this pellet stove. The stove’s flue collar is 3” in
diameter. An approved wall thimble or approved ceiling firestop must be
used when the pellet pipe passes through a combustible wall or ceiling.
The stove’s combustion blower pressurizes and pushes flue gases out
the pellet pipe. As a result, all pipe joints should be locked together or
screwed with three screws if the pipe does not have a locking system
and sealed with high temperature silicone. The pipe should be siliconed
and fastened with three screws to the stove’s flue collar.
In Canada, where the venting may pass through a wall, or partition of
combustible materials, the installation shall conform to CAN/CSA-B365.
When installing the wall thimble and other venting components, follow
the vent manufacturers instructions. Maintain an effective vapor barrier
at the location where the chimney or other component penetrates to the
exterior of the structure.
The longer the run of pipe and the more elbows used, the greater the
resistance to the flow of flue gases. Four inch diameter pellet pipe is
recommended for pipe runs greater than 15 feet or when a number of
elbows are used.
To aid in cleaning, whenever possible, the venting system should include
a tee with clean out attached to the flue collar on the stove. Do not install
back to back elbows right off the back of the stove in any installation.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING
SYSTEM OF THIS UNIT. DO NOT CONNECT THIS UNIT TO A
CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
Horizontal installations that terminate without any vertical sections of
pipe are approved; however, wind may direct flue gases toward the house
causing discoloring problems. For this reason, horizontal and up 5 feet or
horizontal and through the eave installations are recommended.
Wood Stove
Pipe Retrofit
The Winslow PS40
stove stove can be
vented into existing
6” or 8” diameter
wood stove pipe.
45°
90°
Horizontal and UP 5’
Horizontal and Up
Through the Eave
1 foot
minimum
Horizontal
Figure 12
Figure 15
Figure 14
Figure 13
INSTALLATION