SPECIFICATIONS: Model L30 DVF-2
PAGE 26
Flue Size 4” – Top Vent
Intake Pipe 6.625” (6 5/8”)
Height Overall 30 5/8”
Height 29 1/8”
Width 30 1/8”
Depth 16 1/8”
Fuel Natural Gas (standard)
(or) LP Gas (convertible).
Gas inlet 3/8” NPT-Male/Flex Line
(or) remove flex, 3/8” NPT–Female Flare.
Performance Variable Flame Control.
Features High Efficiency Heat Exchanger.
Natural Convection & Radiant Heat.
Standing Pilot/Operates During Power
Outages. Remote Control & Wall
Thermostat Capable.
Technical Honeywell Combination Gas Control
Features Valve, Millivolt - VS8520E
Pan Burner with Tuned Ports.
Radiant & Fan Assisted Convection Heat.
Safety Test Tested and certified by CSA to ANSI stan-
dards. Z21.88-1998 CSA 2.33a - M98.
Vented Gas Fireplace Heater
Heat Input 25,000 to 37,000 BTU’s (Nat. Gas)
28,000 to 35,000 BTU’s (Propane)
Ship Weight 200 lb.’s
Dimensions shown are approximations only (+/- ¼”)
Top View
Side View
SPECIFICATIONS
GAS TYPE NATURAL
GAS
PROPANE
(LP)
MINIMUM CLEARANCES TO COMBUSTIBLES
Orifice Size #31 -.120 #50-.070” Back Wall Min. 2 In. / 51 mm
Minimum Supply Pressure 4.5” WC 10.5” WC Side Wall Min. 12 In. / 305 mm
Maximum Supply Pressure 10.5” WC 13.0” WC Corner (45° angle)
HIGH SETTING stove corner to wall, min. 4 In. / 102 mm
Manifold Pressure 3.5” WC 10.0” WC (Floor to) Ceiling Height Min. 65 In. /1651 mm
Input BTU/HR / Efficiency 37,000/76% 35,000/79% Alcove Min. Height 65 In. /1651 mm
LOW SETTING Alcove Min. width 54 In. /1372 mm
Mainfold Pressure 1.8” WC 6.6” WC Alcove - Max. Depth into
Input BTU/HR 25,000 28,000 stove face to alcove opening 24 In. / 610 mm
Altitude - U.S.A. 0-4,500 Ft. (0-1372M) No derating
Altitude - Canada 0-4,500 Ft. (0-1372M) No derating
* With the orifice, manifold pressure and input ratings shown above.
For installation higher than altitudes shown above, reorifice per Gas
Codes
The efficiency rating of the appliance is a
product thermal efficiency rating determined
under continuous operating conditions and was
determined independent of any installed system.
This Appliance is equipped at the factory for the use with Natural Gas or Propane (LP). Appliances using propane must
be field conversed using the LP Conversion Kit supplied with appliance.