35
t.t)
n
o
Itl
n
30
25
20
15
10
Pressure Drop (PSI) vs. Flow Rate (GPM)
420 Series
9.5gpm @ 10 psi
0 I
0 1 2 3 4 5 6 7 8 9 1011 121314151617181920212223
Flow Rate (GPM)
FIG. 60
OTHER SPECIFICATIONS
Type of ion exchange material (resin) high capacity
Amount of resin (cu. ft.) 1.20
Rated Softening Capacity (Grains @ Pounds Salt Dose) 12,500 @ 2.5
33,300 @ 9.4
42,300 @ 16.3
Efficiency Rating (Grains / Pound of Salt @ Minimum Salt Dose) 5010 @ 2.5
Rated Service Flow Rate (gpm) 9.5
Pressure Drop at Rated Service Flow Rate (psi) 10
Intermittent Flow Rate @ 15 psi (gpm) "k 13.0
Max. Drain Flow Rate (gpm) 2.0
"k Intermittent flow rate does not represent the maximum service flow rate used for determin-
ing the softeners rated capacity and efficiency. Continuous operation at flow rates greater
than the service flow rate may affect capacity and efficiency performance.
These systems conform to NSF / ANSI 44 for the specific performance claims as verified and
substantiated by test data.
The efficiency rating is only valid at the minimum stated salt dosage. These softeners were
efficiency rated according to NSF /ANSI Standard 44.
Contaminant
Barium
Radium 226/228
Influent Challenge Level
10 +10% mg/L
25 pCi/L
Maximum Allowable
Product Water Level
2.0 mg/L
5 pCi/L
Questions? Call The Kenmore Water Line 1-800-426-9345
37