SECTION 5 SERVICE TECH INFORMATION
I
5A. TROUBLESHOOTING
Keep this manual with your water softener. If repairs are needed, the service technician must have the information
on the following 8 pages. For telephone assistance, call toll free, 1-800_i26-9345.
WIRING SCHEMATIC
Transformer
Tank Light _) /_
Motor, 24VAC _._
BACK OF FACEPLATE I
77'7_1
Turbine
Sensor
o,...._ Nc Position
bm ONO Switch
FACEPLATE
F
Kenmore_
_C_Assistame
I_00-426-9345
[]
[]
LOW SALT
[]
[]
Gen_ IIWaterSo_en_
J
ALWAYS MAKE THESE INITIAL CHECKS FIRST
1. Does the time display show the correct time of day?
--If display is blank, check power source to the soft-
ener.
--If time is flashing, power was off for over 24 hours. The
softener resumes normal operation but regenerations
occur at the wrong time.
--If an error code (Example: Err3) shows in the faceplate
display, go to AUTOMATIC ELECTRONIC DIAGNOS-
TICS.
2. Plumbing bypass valve(s) must be in full service
position.
3. The inlet and outlet pipes must connect to the softener
inlet and outlet respectively.
4. Is the transformer plugged into a "live", grounded wall
outlet, and the power cable fastened securely?
5. The valve drain hose must be free of kinks and sharp
bends, and not elevated over 8 ft. above the floor.
REMOVE THE TOP COVER AND SALT TANK COVER
o
°
ls there salt in the storage tank? If you are using
potassium chloride, did you reset the timer in step 5,
page 7.
Is the brine tubing connected? (See water flow
diagrams).
8. Is the brine valve float set right? (See page 24).
. Press the #1 SELECT button 2 times to display the
hardness setting. Be sure it is the correct setting for the
household's water supply. (Make a hardness test of the
raw water and compare with the hardness setting. Also
test a soft water sample to verify if a problem exists.)
Press the #1 SELECT button twice more to return to
present time in the display.
If you do not find the problem after making initial checks,
do the MANUAL INITIATED ELECTRONIC DIAGNOSTICS,
and the MANUAL ADVANCE REGENERATION CHECK.