Kenmore 625.34867 Water System User Manual


 
SECTION 4 OTHERTHINQSTOK.OW
4A. DIMENSIONS/SPECIFICATIONS
BYPASS VALVES
SINGLE
PULL OUT
forservice
-I IN
for bypass
3 - VALVE
close bypass valve
open inlet & outlet valves Outlet
FOR BYPASS
open bypass valve
close inlet & outlet valves
Bypass
Valve
bInlet
Valve
/ \
I
I
I
I
I
A
C
E
INCHES CM
A Salt Tank Height 40-1/4 102.2
B Resin Tank Diameter (nominal) 9 22.7
C Resin Tank Height (nominal) 40 101.6
D Inlet-Outlet Height 41-1/2 105.4
E Overall Height 47 119.4
F1 Length 19-1/2 49.5
F2 Width 16-1/2 41.9
-- Distance between inlet-outlet 3-7/8 9.8
center lines
MODEL NO. 625.348670 TIMER HF CODE HF32
NOTE: Please see the rating decal for water softener operating capacity, salt usage and service flow rate/pressure
loss performance specifications. Performance specifications are validated by the Water Quality Association
(WQA). The rating decal is located on the rim, under the salt hole cover (see page 30).
WATER SUPPLY TO WATER SOFTENER
MINIMUM WATERSYSTEM FLOW (gpm) ................ 3
MINIMUM-MAXIMUM WATERPRESSURE (psi) ..... 20-120
MAXIMUM WATERTEMPERATURE (°F) ............... 120
MAXIMUM WATERHARDNESS (gpg) ................. 110
MAXMUM "CLEARWATER"IRON (ppm) ................. 6
SALT FOR WATER SOFTENER
TYPE OF SALT NEEDED ................... Nugget/Pellet
ALTERNATETYPE OF SALT .. Pure,evaporated,compacted
water softenersalt
STORAGE CAPACITY(pounds)....................... 200
TYPE OF ION EXCHANGE MATERIAL (resin) High Capacity
AMOUNT OF RESIN (cu.ft.) .......................... 1.0
REGENERATION (RECHARGE) CYCLE TIME (min.)
FILL (NaCL setting) ........................... 2.7-10.6
FILL (KCI setting) ............................. 3.8-12.6
BRINING / BR. RINSE ........................ 120-135
BACKWASH ....................................... 7
FAST RINSE ....................................... 3
TOTAL REGENERATION TIME ............ 139.4--164.4
gpm = gallons per minute
gpg = grains per gallon
psi = pounds per square inch
ppm = parts per million